12.07.2015 Views

z/OS V1R9.0 TSO/E Command Reference

z/OS V1R9.0 TSO/E Command Reference

z/OS V1R9.0 TSO/E Command Reference

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

LOADGO <strong>Command</strong>set is named according to the data set naming conventions. You cansubstitute an asterisk (*) for the data set name, if you want to have thelistings displayed at your terminal. If you specify the MAP operand, thenPRINT is the default.NOPRINTspecifies no listings are to be produced. This operand suppresses the MAPoperand. If both PRINT and NOPRINT are omitted and you do not use theMAP operand, then NOPRINT is the default.AMODE(24 | 31 | 64 | ANY | MIN)specifies the addressing mode for the module to be loaded. If the AMODEoperand is not specified, AMODE defaults to the AMODE of the main entrypoint. Valid AMODE values are:24 indicates that the module is invoked in 24-bit addressing mode.31 indicates that the module is invoked in 31-bit addressing mode.64 indicates that the module is invoked in 64-bit addressing mode.ANYindicates that the module is invoked in either 24-bit or 31-bit addressingmode.MINcauses the binder to set the AMODE to the most restrictive AMODE of allcontrol sections in the module. In this respect, 24 is more restrictive than31, which is more restrictive than ANY.The MIN keyword is used only to control binder processing. It assists thebinder in determining the resultant AMODE of the module. However, MIN isnever used as an AMODE itself and will not appear in the directory entry ofthe resultant load module or program object.For more information see z/<strong>OS</strong> MVS Program Management: User’s Guideand <strong>Reference</strong>.RMODE(24 | ANY | SPLIT)specifies the residence mode for the module to be loaded. If all control sectionsare not specified as RMODE(ANY), RMODE defaults to 24. If any section of theload module has an RMODE(24), RMODE defaults to 24. Valid RMODE valuesare:24 to indicate the module must reside below the 16 MB lineANY to indicate the module can reside anywhere below the 2GB bar invirtual storageSPLIT to indicate that the program object is to be split into two segmentsaccording to the RMODE of the CSECTs. SPLIT is supported only forPM2 or PM3 format program objects.LIB(data_set)specifies names of one or more library data sets that are to be searched to findmodules referred to by the module being processed (that is, to resolve externalreferences).BINDER | NOBINDERBINDERspecifies that MVS use binder services for this load module or objectChapter 1. <strong>TSO</strong>/E commands and subcommands 185

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!