9. Insert the hydraulic cylinder (Item F - Fig. 41) and ensure that the bottom of thecylinder is on the clamping plate (Item D - Fig. 41).10. Connect the hoses of the hydraulic pump (see Fig. 41).11. Operate the hydraulic cylinder using the manually operated pump (see Fig. 42)until the complete segment ring (Item 9) can be removed.FIG. 42: OPERATE HAND PUMPFIG. 43: REMOVE COMPONENTSOF SEGMENT RING12. Remove components of the segment ring (see Fig. 43).IMPORTANT: Do not touch segment grooves with hand. The hydraulic press mayfail. Use tools to remove stuck segments.13. Remove the clamping device.14. Remove the support ring (Item 8 - Fig. 37, also see Fig. 44).15. Removal of the complete control stud. Fit the connection air hose to the threadof the control tube and use to help remove the complete control stud (shownwithout air hose connected) (see Fig. 45).FIG. 44: REMOVE SUPPORT RINGFIG. 45: REMOVE CONTROL STUD<strong>TT</strong> TECHNOLOGIES, INC.27