FadalMaintenance ManualScheduledMaintenanceThe maintenance schedule is based on machine usage of eight hours a day,five days a week.Daily MaintenancePerform the following daily:1) Cleaninga. Remove the chips and debris surrounding the proximity switch inducingblock.b. Remove the chips and debris that have accumulated on the invertedmoving body of the tool pot.c. Clear the tool changing mechanism of all debris before any operation.2) Inspection:a. Check the parts of the tool falling mechanism for damage and wear.Add grease to the sliding base of the tool falling mechanism and thepull rod.b. Check the parts of the tool pots, tool discs, and snap rings for damageand tightness.Weekly MaintenancePerform the following weekly:1) Greasing:a. Grease the claws of the tool changing arm unit.b. Grease the tip of the release pin of the tool changing unit.Miscellaneous MaintenancePerform the following as necessary:1) Change the lubricant annually or as needed. The re<strong>com</strong>mended lubricant isSAE 90-140. The Dual Arm <strong>Tool</strong> Changer uses approximately 5 liters (1.3gallons).156 <strong>Section</strong> <strong>05</strong>: <strong>Automatic</strong> <strong>Tool</strong> <strong>Changers</strong> March 2003