21.07.2015 Views

[Medical college and Hospital] - Seiaacg.org

[Medical college and Hospital] - Seiaacg.org

[Medical college and Hospital] - Seiaacg.org

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

the Oil <strong>and</strong> Grease Traps where the oil <strong>and</strong> grease is removed from the Effluent.The Effluent free from Grit, Oil <strong>and</strong> Grease enter the collection sumps.(Equalization sump).b. TreatmentThe Effluent from the collection sumps is pumped into the Aeration tank workingon the principle of diffused aeration with the help of Fine Bubble Jet diffusers.From Aeration Tank, the flow is led to Plate Settlers. The settled sludge from thesettling tank is drawn by Non-Clog pumps <strong>and</strong> taken back to aeration tanks formaintaining the required MLSS <strong>and</strong> surplus sludge is led to sludge concentrationunit. The sludge concentration process is activated with the help of PolymersDosing. Concentrated sludge is disposed off for offsite solid disposal treatment.The effluent from the sludge concentration unit is taken back to Aeration tank forfurther treatment. The clarified liquid is withdrawn over weir into the launder <strong>and</strong>from launder it is taken to chlorine contact chamber where it is disinfected withthe help of hypochlorite solution. The disinfected effluent from the chlorinecontact chamber is pumped through Multi-grade Filter <strong>and</strong> finally throughActivated Carbon filter for Gardening/ Horticulture. Part of this disinfected effluentis taken to Mild Steel/RCC/HDPE tank provided for storage of wash water. Fromthe wash water tank, the water is pumped back to Pressure Filter for periodicback washing with the help of both pumps working at a time. The wash out let<strong>and</strong> drain of Pressure filter is led back to aeration tank for further treatment.c. Disposal:The treated water will get utilized in horticulture, DG cooling, external green beltdevelopment <strong>and</strong> site maintenance purpose. The surplus water will be dischargedinto external drain.Storm Water Management:As discussed earlier, most of the storm water produced on site will be harvested f<strong>org</strong>round water recharge, thus proper management of this resource is must to ensure thatit is free of contamination. Contamination of storm water is possible from the followingsources: Oil spills <strong>and</strong> leaks in vehicle parking lots Silt from soil erosion in gardensA detailed “Storm Water Management Plan” will be developed which will consider theabove sources. The plan will incorporate best management practices which will includefollowing:Phone No.: 0788 2294712, 2292683, Fax No.: 0788 2292241Web: www.ch<strong>and</strong>ulalch<strong>and</strong>rakarhospitalbhilai.comEmail: admin_ccmh@sify.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!