Stratus Continuum<br />

4.53 Stratus Continuum<br />

4.53.1 Overview<br />

Stratus Technologies 240 built a line of “Ultra High Availability Fault Tolerant” <strong>PA</strong>-<strong>RISC</strong> (32-bit <strong>PA</strong>-<br />

7100 and 64-bit <strong>PA</strong>-8x00) based servers called Continuum (with a stated availability of 99.999% and<br />

more). These systems feature a great deal of redundancy, peaking in having four CPUs to form one<br />

single logical processor. The <strong>PA</strong>-<strong>RISC</strong>-powered systems were phased out in 2004 in favor of Intel<br />

IA32-based systems (not covered here).<br />

The Stratus Continuum servers ran either Stratus-modified HP-UX 11.00, Stratus VOS (<strong>PA</strong>-<strong>RISC</strong> support<br />

from release 13.0 until 14.7.2) or FTX, Stratus’ own Unix System V Release 4 multiprocessor OS<br />

(however support differed between the 400 and 600/1200 lines).<br />

4.53.2 Hardware Details<br />

I/O<br />

The Continuum 600 and 1200 series are basically the same system, except for the chassis configuration.<br />

The 600 has six slots for the main bus (called the Golf bus), and the rest of the space is filled with I/O<br />

card cages meant for secondary I/O boards. The 1200 has twelve slots for the main bus which occupies<br />

the entire width of the chassis. Secondary I/O boards go into a separate chassis. Both models have<br />

space for two rows of cooling fans on the top, and two rows of disk drives on the bottom (and also<br />

either a QIC or DAT tape drive or CDROM drive). The redundant power supplies with built-in UPS<br />

resides at the very bottom.<br />

The main Golf bus is the main interconnect between the “big” boards. It is also redundant and selfchecking.<br />

The “big” boards consist of the following (all these are FRUs):<br />

� G7xx - CPU and memory boards (of different number and type of processors, speeds and memory<br />

sizes)<br />

� K450 - 4-channel HVD fast wide SCSI and Ether<strong>net</strong> adapter<br />

� K460 - 4-channel HVD fast wide SCSI and Ether<strong>net</strong> adapter<br />

� K470 - A “carrier board” that can contain up to three PMC (PCI-mezzanine) daughter cards<br />

� K600 - Adapter to two PK-buses which connects to the secondary I/O card cages<br />

On the 600 chassis, the six slots consists of two for the pair or CPU/memory boards, and four more<br />

slots for two pairs of “big” boards. On the 1200 chassis, there are slots for two pairs of CPU/memory<br />

boards and four pairs of big boards.<br />

In addition the 600/1200 main chassis also has a pair of Console Controller cards which provides the<br />

RS232 console terminal and RSN modem connectivity. This controller also has a command mode that<br />

allows the operator to type commands on the console to reset the system, power down, power up, etc.<br />

It runs on “housekeeping power” that is independent of the rest of the system. The Console controller<br />

also contains some environmental monitoring circuitry that checks the chassis internal temperature and<br />

will increase the cooling fan speed if necessary (the fans themselves are also hot-swappable FRUs).<br />

The secondary I/O chassis can be used to plug in a wide array of I/O boards (all Stratus proprietary).<br />

These boards are also used on the XA/R line. FTX supported many of the communications boards<br />

240 http://www.stratus.com<br />