Installation Manual - Future Pipe Industries
Installation Manual - Future Pipe Industries
Installation Manual - Future Pipe Industries
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
8. Mechanical couplers<br />
Before starting the assembly of a mechanical coupler check if all safety precautions have been taken and all necessary<br />
tools and materials are available. See chapter 12 and 8.1.<br />
8.1. Tools for mechanical couplers<br />
For Straub and Taylor Kerr: - Allen key and torque wrench.<br />
For Dresser, Viking Johnson and Inland couplers: - ring spanner.<br />
Wavistrong pipes have lower torques than steel pipes, depending on the wall thickness.<br />
Contact FPI for more information.<br />
8.2. Mechanical couplers<br />
Mechanical couplers, normally used for steel pipes, can also be used: e.g. Straub, Viking Johnson, Dresser,<br />
Taylor Kerr. However, restraining couplers should not be used as these may damage the Wavistrong pipes.<br />
Fig. 8.2.a.<br />
With these couplers connections between R.T.R.P. and other materials can be made. Reducing couplers are available<br />
for pipes with different outside diameters. When using these type of couplers, the cut R.T.R.P. pipe ends must be sealed<br />
with a resin coating. See lamination instructions. These couplers may also be used for quick repairs of underground<br />
pressure systems.<br />
As these couplers do no provide axial restraint, they must not be used within a specific distance of a change of<br />
direction as this can cause separation of the joint. One of the factors determining this length is the friction value<br />
of the surrounding soil. Adequate fixing of above ground pipe systems is required.<br />
The torques given on the joints do not apply to Wavistrong. For the correct torques, contact <strong>Future</strong> <strong>Pipe</strong> <strong>Industries</strong>.<br />
After installation of Dresser couplers the stopper bolt must be removed and replaced by a plug in order to prevent<br />
damage of the pipe wall.<br />
Wavistrong <strong>Installation</strong> <strong>Manual</strong><br />
32