2.3. Storage of material<br />
In order to avoid damage to the stacked pipes, the following rules are important:<br />
A Do not lay the pipes directly on the ground, onto rails or concrete floors. Provide a flat surface.<br />
Fig. 2.3.a.<br />
B Ensure suitable supports are used for example wooden beams, measuring 10 x 5 cm. To avoid damage to<br />
machined pipe ends, stacking should be undertaken with care. The machined ends must be protected for example<br />
by polyethylene covered straw mats or polyethylene netting. The socket and spigot ends must not touch each other.<br />
C The pipes can be stacked economically by alternating the spigot and the socket, as illustrated below. In order to<br />
avoid bending of the pipes, the beams should be laid directly above each other in a vertical line. Supports should<br />
be spaced at a max. of 3 metre intervals and about 1 metre from each end. The width of the supports should be<br />
at least 10 cm. The maximum allowable stack height is 1.5 metres. However, for diameters of 800 mm and above,<br />
a maximum of 2 pipes may be stacked one on top of the other.<br />
Fig. 2.3.b.<br />
~1m.<br />
max. 3m.<br />
D If the product is stacked too high for long storage periods (6-12 months) and subjected to high temperatures,<br />
the supports may cause flattening. It is recommended that the product ( in particular machined parts) is stored<br />
under tarpaulins or (white) polyethylene sheeting.<br />
E <strong>Pipe</strong> stacks should have side supports or blocks to prevent rolling or slipping of the stack during stormy weather.<br />
F Store rubber o-rings, gaskets, plastic locking strips, adhesive kits, resins, hardeners, woven roving and lubricants<br />
in its original pack, below 35(C. Keep dry, away from frost, direct sunlight and ozone.<br />
Observe the shelf life of the adhesives and resins. It is preferable to order these as required.<br />
Wavistrong <strong>Installation</strong> <strong>Manual</strong><br />
8<br />
max. 3m. ~1m.