4.0 PROCESS DESCRIPTION<br />

4.1. PROCESS DATA<br />

� The bidders shall design the skid considering the worst case process condition<br />

scenario.<br />

� The set pressure of Pilots <strong>for</strong> PCV & SDV shall cover the complete range of inlet<br />

& out let condition. For PCV, SDV , if one pilot is not able to cater the complete<br />

range then installed pilot with additional loose springs shall be supplied to cover<br />

the entire range. The pilot should be designed such as to handle traces<br />

of moisture and condensate. Special care to be paid <strong>for</strong> dealing with<br />

the problem arising from possible condensation due to pressure<br />

reduction. Provision <strong>for</strong> heating of pilot gas to be provided.<br />

� The main line PSVs shall be of full capacity (each PSV shall cater complete flow<br />

capacity). The PSVs <strong>for</strong> each Filter shall be designed <strong>for</strong> fire case. The Mainline<br />

CRVs shall be redundant (1 working + 1 standby) and each independent CRV<br />

shall cater flow of 1% of the rated flow capacity. The PSV / CRV to be designed<br />

in such a way that the set pressure can be adjusted within the whole operating<br />

and design pressure range/ set points. Separate spring(s) shall be provided, if<br />

one spring is not sufficient to meet the requirement.<br />

4.2. Detailed Process conditions:<br />

ITE<br />

M<br />

NO<br />

FLOW<br />

(MAX/NORMAL/MI<br />

N)<br />

1 -/6/* MMSCMD<br />

Check Metering<br />

System<br />

2 2/1.3/* MMSCMD<br />

SKID<br />

<strong>GAIL</strong> (INDIA) LTD<br />

NEW DELHI<br />

INLET<br />

PRESSUR<br />

E RANGE<br />

60-92<br />

kg/cm2<br />

60-92<br />

kg/cm2<br />

IN LET<br />

TEMPERATUR<br />

E RANGE<br />

-5 to 55 deg<br />

C<br />

-5 to 55 deg<br />

C<br />

SCOPE OF WORK<br />

OUT LET<br />

PRESSUR<br />

E RANGE<br />

60-92<br />

kg/cm2<br />

40-47<br />

kg/cm2<br />

* Min flow to be specified as per meter turn down<br />

CLASS<br />

RATING<br />

Inlet/Ou<br />

t let<br />

600#<br />

/600#<br />

600#<br />

/300#<br />

Typical<br />

Gas<br />

compositio<br />

n<br />

As given<br />

below<br />

As given<br />

below<br />

4.3. Specific Gravity of 0.57-0.72 shall be considered, Temperature range -5-<br />

55 deg celcius <strong>for</strong> the purpose of sizing.<br />

Design Temperature: -29 to 65 deg C.<br />

Design Pressure : 92 Kg/cm2(g)<br />

DOCUMENT NO. REV-0<br />

0015-01-08-06-001-SW<br />

Page 28 of 43<br />

Copyright <strong>GAIL</strong> – All rights reserved