14. SPECIAL NOTES - D1A<br />

ITEM SIZE DESCRIPTION<br />

MAINTENANCE JOINTS ALL FLANGED, TO BE KEPT MINIMUM<br />

PIPE JOINTS 1.5” & BELOW SW COUPLING<br />

<strong>GAIL</strong> (India) Limited<br />

New Delhi<br />

2.0” & ABOVE BUTT WELDED<br />

DRAINS ON LINES ≤1.5” REFER <strong>GAIL</strong> STD. S-05-01-003<br />

ON LINES ≥2.0” AS PER P&ID OR 0.75” REFER STD.S-05-01-004<br />

VENTS ON LINES ≤1.5” REFER <strong>GAIL</strong> STD. S-05-01-003<br />

ON LINES ≥2.0” AS PER P&ID OR 0.75”. REFER STD. S-05-01-003<br />

TEMP. CONN 1.5” FLANGED, INSTALLATION AS PER <strong>GAIL</strong> STD.<br />

S-05-01-005<br />

PRESS. CONN 0.75” SW NIPPLE WITH GATE VALVE TO SPEC AS PER STD.<br />

S-05-01-006<br />

PIPING MATERIAL SPECIFICATION -<br />

CAPACITY AUGMENTATION OF AURAIYA-<br />

JAGDISHPUR PIPELINE (PHASE-I)<br />

SPECIFICATION REV-0<br />

0015-01-05-02-001<br />