Fiber Optic Design Guide - Maite y Mario
Fiber Optic Design Guide - Maite y Mario
Fiber Optic Design Guide - Maite y Mario
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
.818"<br />
(20.8)<br />
.600"<br />
(15.2)<br />
2.30"<br />
(58.4)<br />
.643"<br />
(16.3)<br />
.600"<br />
(15.2)<br />
2.38"<br />
(60.5)<br />
<strong>Fiber</strong> Accessories<br />
<strong>Fiber</strong> <strong>Optic</strong> Stand Alone Power Supplies, <strong>Fiber</strong> <strong>Optic</strong> Jumper Cables<br />
2.07"<br />
(52.6)<br />
1.78"<br />
(45.2)<br />
.495"<br />
(12.6)<br />
0.69"<br />
(17.5)<br />
(Wire with white stripe is positive)<br />
.495"<br />
(12.6)<br />
0.70"<br />
(17.8)<br />
(Wire with white stripe is positive)<br />
1.59"<br />
(40.4)<br />
1.55"<br />
(39.4)<br />
7419<br />
7417<br />
Power Supply ACCS-PS-90 ACCS-PS-170 ACCS-PS-200<br />
Specifications #7417 #7419 #7418 Units<br />
AC Input: 120 120 120 VAC<br />
60 60 60 Hz<br />
DC Output: 9 15 15 VDC<br />
Voltage (Nominal): 0.3 0.4 1 A<br />
No Load Voltage: 14.3 19 N/A VDC<br />
Output Stability: N/A +0.5 N/A V @ rated load<br />
Operating Temperature: 0 to +40 0 to +40 0 to +40 ˚C<br />
Enclosure: Plastic Plastic Plastic<br />
3.1"<br />
(78.7)<br />
2.0"<br />
(50.8)<br />
0.69"<br />
(17.5)<br />
E25-1<br />
7419 7418<br />
7418<br />
7417<br />
To complete your fiber installation, Blonder Tongue provides a wide assortment of<br />
optical jumper assemblies. The jumper cables are available in single mode or<br />
multimode versions, with either FC/APC, SC/APC, or ST connectors.<br />
Specifications<br />
<strong>Fiber</strong> <strong>Optic</strong> Jumpers<br />
Cable Loss or Attenuation:<br />
Insertion Loss<br />
At 1310 nm please plan on maximum attenuation of<br />
.5 dB per KM. Average should be .4 dB per KM<br />
At 1550 nm please plan on maximum attenuation of<br />
.4 dB per KM. Average should be .3 dB per KM<br />
(FC/APC & SC/APC): Average .09 dB<br />
Back Reflection<br />
Maximum .3 dB<br />
(FC/APC & SC/APC): Average -70 dB<br />
Maximum -65 dB<br />
NOTES:<br />
* Back reflection is measured with the HP 8504B, power loss with the HP 8153A<br />
See Blonder Tongue’s CATV Reference <strong>Guide</strong> for <strong>Optic</strong>al Cable Assemblies<br />
XX = Connector Style:<br />
FA = FC/APC FU = FC/UPC SA = SC/UPC SU = SC/UPC<br />
ST = ST BI = Biconical SM = Mini SC<br />
ST<br />
SC/APC<br />
FC/APC<br />
2.0"<br />
(50.8)<br />
ORDERING INFORMATION:<br />
ACCS-PS-90<br />
Stock No. 7417<br />
Use with BT Stock Number: 7422-S<br />
ACCS-PS-170<br />
Stock No. 7419<br />
Use with BT Stock Numbers: 7423-S,<br />
7441-S, 7442-S, 7443-S, 7444-S, 7451-S,<br />
7452-S, 7463-S, 7473-S, 7433-S, 7432-S,<br />
7471-S, 7472-S, 7425-S<br />
ACCS-PS-200<br />
Stock No. 7418<br />
Use with BT Stock Numbers:<br />
7461-S, 7462-S<br />
SINGLE MODE CABLES<br />
FIUJ-S4-1-XX<br />
Stock No. 7493XX 1 Meter<br />
FIUJ-S4-3-XX<br />
Stock No. 7494XX 3 Meter<br />
FIUJ-S4-6-XX<br />
Stock No. 7495XX 6 Meter<br />
FIUJ-S4-15-XX<br />
Stock No. 7497XX 15 Meter<br />
FIUJ-S4-50-XX<br />
Stock No. 7496XX 50 Meter<br />
XX = Connector Style - See Notes<br />
MULTIMODE CABLES<br />
FIUJ-M8-1-XX<br />
Stock No. 7498XX 1 Meter<br />
FIUJ-M8-3-XX<br />
Stock No. 7499XX 3 Meter<br />
FIUJ-M8-6-XX<br />
Stock No. 7500XX 6 Meter<br />
XX = Connector Style - See Notes<br />
<strong>Fiber</strong> <strong>Optic</strong>s