Scenario Annual Dose Criteria Public Worker Assessment Capacity<br />

Used for Assessment<br />

Constraint?<br />

Exposure from Gas 0.02 mSv/yr Public (GRA) x 8.10<br />

Considered as a<br />

Generation from the<br />

Annex B potential<br />

Landfill<br />

constraint to<br />

landfill capacity<br />

Exposure to Wildlife 10 microgray/hr x x 8.11<br />

Not used to<br />

from all sources<br />

Annex B define landfill<br />

capacity<br />

External dose from 0.02 mSv Public (GRA) x 8.12<br />

Not considered<br />

emplaced wastes<br />

Annex B as a constraint<br />

to landfill<br />

capacity<br />

because the<br />

resulting doses<br />

are trivial<br />

Post –Closure not expected to occur<br />

Exposure by Using 3 mSv Public (GRA and x 8.13<br />

Has the potential<br />

Groundwater from a HPA)<br />

Annex B to be a<br />

Borehole<br />

constraint to<br />

Constructed at the<br />

Boundary of the<br />

Landfill<br />

landfill capacity<br />

Exposure by 3 mSv Public or Worker 8.14<br />

Has the potential<br />

Intrusion into the (GRA and HPA)<br />

Annex B to be a<br />

Emplaced Waste<br />

constraint to<br />

Post Closure of the<br />

Landfill<br />

landfill capacity<br />

Other potential scenarios are discussed in Annex B and have not been assessed for documented reasons.<br />

8.0.5 Some other potential scenarios are discussed in Annex B and have not been<br />

assessed for documented reasons. Additionally:<br />

- The aircraft crash scenario is discussed with the dropped load scenario.<br />

- A scenario involving drilling into the waste form for construction of new<br />

sampling or leachate wells is not discussed because this would be<br />

executed with knowledge under appropriate regulations with appropriate<br />

precautions as necessary.<br />

- The effects of very long term climate change are not assessed because<br />

the site is already permitted as a hazardous site and LLW disposal gives<br />

rise to no additional considerations in respect of flooding, coastal erosion<br />

or sea level rises. Future glaciation would have similar or lesser effects<br />

than the “residential intrusion scenario” considered in 8.14.<br />

- The effects of seismic events. The engineered containment structures at<br />

the site are not formed of brittle materials such as concrete that may<br />

fracture as a result of a severe earthquake. The HDPE and clay lining<br />

materials have a high shear strength and have the flexibility to withstand<br />

Application for disposal of LLW including HV-VLLW under RSA 1993,<br />

for the East Northants Resource Management Facility:<br />