<strong>Manual</strong> <strong>TCIP</strong> <strong>6<strong>03</strong></strong>-<strong>03</strong><br />
3.3. Menu tree and functionality<br />
In the following, all the menu points and their functions are described.<br />
3.3.1. Hardware/system<br />
This point encompasses all the functions which affect the hardware or software.<br />
The inputs, outputs and reader are dynamically managed. In total, 24 input modules such as code lock modules, Easikey<br />
modules or fingerprint modules are supported. In addition to this are also the „local“ inputs and outputs on the<br />
<strong>TCIP</strong> <strong>6<strong>03</strong></strong>-... and the extensions FSM 740-... and SCE 640-...<br />
3.3.1.1. Inputs<br />
The „Hardware/System -> Inputs“ menu point provides a list of all configured inputs. A difference is drawn between<br />
„local“ and „external“ inputs.<br />
The „local“ inputs (inputs E1–E5) are located at the <strong>TCIP</strong> <strong>6<strong>03</strong></strong>-01. „External“ inputs are addressed via the<br />
FSM 740-... and SCE 640-... . If no FSM 740-... is found on startup (Power ON) of the <strong>TCIP</strong> <strong>6<strong>03</strong></strong>-..., this function is disabled.<br />
Fig. 4: List of inputs<br />
Column name Description<br />
Name This column describes the name of the input.<br />
Door name If the input is assigned to a door, the door name appears here.<br />
Type There are two different input types (door sensor and door button). One of these two is displayed<br />
here when the input is in use.<br />
Port Here, the port number of an input is displayed.<br />
Location A distinction is made between two different locations. The location „local“ stands for local<br />
inputs E1–E4. „Vario bus“ stands for external inputs via the FSM 740-...<br />
Table 2: List of inputs: Column description<br />
Two actions „Change“ and „Remove“ are assigned to each configured input. Using „Change“ the name of the input and<br />
the device number can be changed. The action „Remove“ removes the input.<br />
However, these actions are subject to a number of restrictions:<br />
• If an input is assigned to a door, this can no longer be changed or removed.<br />
• Local inputs cannot be removed.<br />