3.3. Menu tree and functionality<br />

In the following, all the menu points and their functions are described.<br />

3.3.1. Hardware/system<br />

This point encompasses all the functions which affect the hardware or software.<br />

The inputs, outputs and reader are dynamically managed. In total, 24 input modules such as code lock modules, Easikey<br />

modules or fingerprint modules are supported. In addition to this are also the „local“ inputs and outputs on the<br />

<strong>TCIP</strong> <strong>6<strong>03</strong></strong>-... and the extensions FSM 740-... and SCE 640-...<br />

3.3.1.1. Inputs<br />

The „Hardware/System -> Inputs“ menu point provides a list of all configured inputs. A difference is drawn between<br />

„local“ and „external“ inputs.<br />

The „local“ inputs (inputs E1–E5) are located at the <strong>TCIP</strong> <strong>6<strong>03</strong></strong>-01. „External“ inputs are addressed via the<br />

FSM 740-... and SCE 640-... . If no FSM 740-... is found on startup (Power ON) of the <strong>TCIP</strong> <strong>6<strong>03</strong></strong>-..., this function is disabled.<br />

Fig. 4: List of inputs<br />

Column name Description<br />

Name This column describes the name of the input.<br />

Door name If the input is assigned to a door, the door name appears here.<br />

Type There are two different input types (door sensor and door button). One of these two is displayed<br />

here when the input is in use.<br />

Port Here, the port number of an input is displayed.<br />

Location A distinction is made between two different locations. The location „local“ stands for local<br />

inputs E1–E4. „Vario bus“ stands for external inputs via the FSM 740-...<br />

Table 2: List of inputs: Column description<br />

Two actions „Change“ and „Remove“ are assigned to each configured input. Using „Change“ the name of the input and<br />

the device number can be changed. The action „Remove“ removes the input.<br />

However, these actions are subject to a number of restrictions:<br />

• If an input is assigned to a door, this can no longer be changed or removed.<br />

• Local inputs cannot be removed.<br />

A new external input can be created using the action „New“.<br />