Manual TCIP 603-03 TCIP SRV 603-0 - Siedle
Manual TCIP 603-03 TCIP SRV 603-0 - Siedle
Manual TCIP 603-03 TCIP SRV 603-0 - Siedle
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Manual</strong> <strong>TCIP</strong> <strong>6<strong>03</strong></strong>-<strong>03</strong><br />
Fig. 43: Door set-up – Add door 1<br />
The anti-passback option is activated to ensure that no-one is able to log in twice. A user must always log in and out<br />
again before access will be afforded again. The anti-passback option only works with defined entrance and exit readers of<br />
a door. A stored output reader is not controlled by a time profile.<br />
Fig. 44: Door set-up – Add door 2<br />
Two input readers have been assigned. Both readers are linked by a logical AND. This means that a successful login process<br />
by the same user must be registered at both readers within the specified time period (timeout).<br />
Fig. 45: Door set-up – Add door 3<br />
Using the „Log entry“ time level of the sensor, it is possible to define from which time during which the door remains<br />
open following a successful login an entry should appear in the event log. The second time „Alarm“ initiates a signal at<br />
the reader (see reader configuration): „Alarm with door open“).<br />