APPENDIX 2.8<br />

ENGINE ROOM - START REFRIGERATION,<br />

BLAST FREEZER, AIR CONDITIONER<br />

START DOMESTIC FREEZER AND CHILLER (404A)<br />

1. Close main circuit breaker (on switchboard) and distribution switch (E.R. frig. Control<br />

board).<br />

2. Close freezer and chiller doors, turn on main switch and two solenoid valves located<br />

port side of the dry provision store.<br />

3. Open all sea water cooling valves to fwd S.W. cooling pump.<br />

4. Switch on S.W. cooling pump first, then start the refrigeration compressor. Check<br />

trips on controllers in E R if compressor doesn’t start.<br />

NOTE: Refrigerant valves are left open, back seated, to reduce leaks.<br />

5. To chill fish room: (compressor running), chill fish room by closing fish room<br />

evap/solenoid switch on front of control panel in E.R. and turn on digital temp. read<br />

out behind front panel.<br />

START BLAST FREEZER (404A)<br />

1. Open S.W. valves to/from fwd. S.W. cooling pump including ships side and start if not<br />

already running.<br />

2. Open S.W. valve on inboard end of condenser.<br />

3. Close start switch on frig. control panel.<br />

ACCOMMODATION VENTILATION<br />

1. All switches in air-con control room, one supply and return fan, one Air-Con. Return<br />

and one galley exhaust fan.<br />

2. Leave all switches off when vessel alongside.<br />

START AIR CONDITIONER (R22)<br />

1. Start supply and Air-Con. return fans.(see above).<br />

2. Open two refrigerant valves near pressure gauges.<br />

3. Open all S.W. intake, discharge and overboard valves to aft S.W. pump.<br />

4. Turn on aft S.W. pump and compressor in E.R. above compressor.<br />

5. Turn on S.W. pump first and Air Con. compressor in Air-Con. control room. (Press<br />

reset on differential control in E.R. if compressor doesn’t start).<br />

6. Temperature adjustment near door to control room.<br />