FUEL CLARIFIER OPERATION<br />

APPENDIX 2.15<br />

ENGINE ROOM - CLARIFIER/PURIFIER OPERATION<br />

• Open valve from D.B. and valve today tank at day tank plumbing.<br />

• Open to and from fuel valves and to (or meter) and from ball valves at purifier and<br />

screw down (open) liquid seal valve.<br />

• Turn on clarifier and allow to run up to speed with regulator valve closed.<br />

• Turn on fuel transfer pump briefly to assist prime if necessary.<br />

• When up to speed, open regulator valve to set flow rate and set discharge ball valve to<br />

register 2 bar discharge pressure (lower gauge).<br />

• Set air regulator to 60 psi and then turn on liquid seal valve and hold with air pressure<br />

(valves on heater closed and by-pass valve open).<br />

• Transfer fuel up to 2.8 ton level in day tank.<br />

HYDRAULIC OIL CLARIFIER OPERATION<br />

• Open liquid seal, to and from valves on tank bulkhead and clarifier (7 in all).<br />

• Turn on clarifier and bring up to speed with regulator valve closed.<br />

• Turn on heater, open heater valves and close heater by-pass valve, allow oil to reach<br />

the set temperature while circulating through heater (oil will by-pass clarifier bowl due<br />

to regulator valve closed).<br />

• Open top metering valve, then set to desired flow rate as oil circulates through heater<br />

and clarifier and back to tank. Set back pressure to 2 bar.<br />

• With air pressure on, turn on liquid seal valve and hold with air pressure.<br />

LUBE OIL CLARIFIER OPERATION<br />

• Open to and from valves near M.E. sump and to and from valves at clarifier and screw<br />

down liquid seal valve (7 in all).<br />

• With Main Engine running and oil hot, turn on clarifier with top regulator valve closed.<br />

• Circulate oil through clarifier slowly, using top regulator control valve. Set back<br />

pressure to 2 bar, and with air pressure on, turn on liquid seal control with heater<br />

valves closed and heater by-pass valve open.<br />