07.03 Outputting an Alarm Message Sequence Report<br />

5.6 Step 5: Activating the Project<br />

Manual <strong>WinCC</strong> <strong>V6.2</strong> <strong>Getting</strong> <strong>Started</strong> 105<br />

6ZB5370-0CM02-0BA5<br />

To print out the alarm message sequence report in runtime, click on the<br />

<strong>WinCC</strong> Explorer toolbar button "Activate".<br />

To activate the simulator, go to the Windows taskbar and click on "Start"<br />

"SIMATIC" "<strong>WinCC</strong>" "Tools" "<strong>WinCC</strong> Tag Simulator".<br />

Click on "Edit" "New Tag".<br />

In the dialog box "Tags - Project", select the internal tag "TankLevel" and click<br />

on "OK".<br />

In the tab "Properties", click on the simulation mode "Random".<br />

Enter a minimum value of "0" and a maximum value of "100".<br />

Select the check-box "active".<br />

In the tab "Tags", click on the button "Start Simulation". The table "Tags" will<br />

then display the tag "TankLevel" with its changing values.<br />

In the message window, click on the button "Message List" to view the list of<br />

incoming messages.<br />

Enter appropriate values in the I/O field to also trigger alarm messages of the<br />

monitored tag "AnalogAlarm".<br />

To start the printout of the messages displayed in the message window, click<br />

on the button . The print job you have set up will start.<br />

Illustration 5.5: <strong>WinCC</strong> Project "Qckstart"; Alarm Message Window in Runtime

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!