<strong>SGC</strong> Rapport 2013:277<br />

5 Models<br />

In this section, the system model will be described along with the <strong>gasification</strong><br />

models and the two methods for CO2 capture that has been chosen for model<strong>in</strong>g<br />

(water scrubb<strong>in</strong>g and am<strong>in</strong>e absorption us<strong>in</strong>g N-methyldiethanolam<strong>in</strong>e (MDEA)<br />

and piperaz<strong>in</strong>e (PZ)). The choice was based on availability of models, maturity of<br />

technology and aim of the project. As the project focused on <strong>in</strong>direct <strong>gasification</strong><br />

the models for the MILENA gasifier was chosen to represent the 100 MW th case<br />

and the Agnion gasifier was chosen to represent the 10 MW th case. These also<br />

<strong>in</strong>clude the models for methanation and other necessary process steps. Other<br />

means of CO2 capture, such as membranes, are becom<strong>in</strong>g more commercially<br />

available [47]. However, no model for this type of system was available with<strong>in</strong> the<br />

project and it was therefore decided not to <strong>in</strong>clude it.<br />

The model<strong>in</strong>g work has been performed <strong>in</strong> an iterative fashion work<strong>in</strong>g with several<br />

different models. The cases simulated will be described more <strong>in</strong> detail <strong>in</strong> the<br />

next chapter. However, two general concepts have been <strong>in</strong>vestigated and those<br />

are pre-methanation and post-methanation CO2 <strong>removal</strong>. In figure 18 the different<br />

iterative simulation procedures are described. These two separation modes have<br />

been <strong>in</strong>vestigated <strong>in</strong> a case where larger scale production has been <strong>in</strong>vestigated<br />

(100 MWth <strong>in</strong>put biomass); a smaller case (10 MW th <strong>in</strong>put) has also been considered,<br />

but only for post-methanation CO2 <strong>removal</strong>. The larger scale has been<br />

based on the MILENA gasifier and the smaller one on a scaled-up version of the<br />

Agnion gasifier.<br />

Model<br />

Integration<br />

Simulation<br />

of<br />

Gasification<br />

Simulation of<br />

CO 2<br />

separation<br />

Figure 18. The order of simulation <strong>in</strong> the case of pre-methanation CO 2 <strong>removal</strong><br />

and post-methanation CO2 <strong>removal</strong> respectively.<br />

5.1 System model<br />

The system model is made <strong>in</strong> Aspen PLUS and describes the unit operations necessary<br />

for conversion of biomass to SNG. No <strong>gasification</strong> model is present, <strong>in</strong>stead<br />

the <strong>gasification</strong> is calculated by mass and energy balances based on real<br />

gas composition and energy requirement of the MILENA gasifier. The energy required<br />

for dry<strong>in</strong>g and gr<strong>in</strong>d<strong>in</strong>g is <strong>in</strong>cluded <strong>in</strong> the model, as is the steam requirement<br />

of the gasifier. Downstream the gasifier is a desulphurization step followed<br />

by a pre-reformer that converts lower hydrocarbons and tars <strong>in</strong>to synthesis gas<br />

and methane. The next step is a water-gas shift reactor that sets the H 2:CO ratio<br />

of the synthesis gas to 3:1. Depend<strong>in</strong>g on where the CO 2 separation is placed<br />

there are a few different scenarios available downstream of the water-gas shift.<br />

Svenskt Gastekniskt Center AB, Malmö – www.sgc.se 39