Upgrading a Single Stack Unit<br />

Upgrading a single stacked switch is necessary when the unit was disabled due to an incorrect FTOS<br />

version. This procedure upgrades the image in the boot partition of the member unit from the<br />

corresponding partition in the master unit.<br />

To upgrade an individual stack unit with a new FTOS version, follow these steps:<br />

Step Task Command Syntax Command Mode<br />

1 Download the FTOS image from the master's boot<br />

partition to the member unit, and upgrade the<br />

relevant boot partition in the single stack-member<br />

unit.<br />

2 Reboot the stack unit from the master switch to<br />

load the FTOS image from the same partition.<br />

Figure 17-32 shows an example of how to upgrade an individual stack unit.<br />

Figure 17-32. Upgrading a Single Stack Unit Example<br />

upgrade system stack-unit<br />

unit-number partition<br />

boot system stack-unit unit-number<br />

primary system partition<br />

EXEC Privilege<br />

CONFIGURATION<br />

3 Save the configuration. write memory EXEC Privilege<br />

4 Reset the stack unit to activate the new FTOS<br />

version.<br />

power-cycle stack-unit unit-number EXEC Privilege<br />

FTOS# upgrade system stack-unit 1 A:<br />

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!<br />

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!<br />

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!<br />

!!!!!!!!!!!!!!!!!!!!!!<br />

Image upgraded to Stack unit 1<br />

FTOS# configure<br />

FTOS(conf)# boot system stack-unit 1 primary system: A:<br />

FTOS(conf)# end<br />

FTOS#Jan 3 14:27:00: %STKUNIT0-M:CP %SYS-5-CONFIG_I: Configured from console<br />

FTOS# write memory<br />

Jan 3 14:27:10: %STKUNIT0-M:CP %FILEMGR-5-FILESAVED: Copied running-config to startup-config in flash<br />

by default<br />

Synchronizing data to peer Stack-unit<br />

!!!!<br />

....<br />

FTOS# power-cycle stack-unit 1<br />

Proceed with power-cycle? Confirm [yes/no]:yes<br />