If you need to shut down the <strong>iH</strong> system quickly, use the Fast shut-down option. When you<br />

select Fast shut-down, the following actions will occur (with a small time delay between each<br />

action):<br />

• On an <strong>iH</strong>600 or <strong>iH</strong>1000 system, the HCMB pump is switched off.<br />

• The gas solenoid-valves are opened to switch on the nitrogen purges to the HCDP pump.<br />

• After approximately 15 seconds (for an <strong>iH</strong>80/<strong>iH</strong>600 system) or approximately 30 seconds (for<br />

an <strong>iH</strong>1000 system), the gas solenoid-valves are closed to switch off the nitrogen purges to the<br />

HCDP pump, and at the same time the HCDP pump is switched off.<br />

• The LED on the On button on the Pump Display Terminal (Figure 1-8, item 1) goes off.<br />

5.11 Automatic shut-down<br />

CAUTION<br />

If you select 'Run til crash', the pump(s) can be damaged and you may invalidate any<br />

warranties on the <strong>iH</strong> system equipment<br />

Notes:<br />

The emergency stop button, the emergency stop signal from your control equipment (if fitted) and<br />

the safety sensors (see Section 1.12.3) will still shut down the <strong>iH</strong> system, even if you have selected<br />

'Run til crash'.<br />

Use the Setup/Run Til Crash menu to select 'run til crash'.<br />

'Run til crash' is automatically reset to 'off ' when the <strong>iH</strong> system is disconnected from the<br />

electrical supply, or the electrical supply is switched off.<br />

Normally, if an alarm condition exists, the <strong>iH</strong> control system will shut-down the <strong>iH</strong> system.<br />

If required, you can request 'run til crash' operation. In this mode of operation, most alarm<br />

conditions will be ignored and the pump(s) will continue to operate. Note however that for<br />

safety reasons the following alarms will shut down the <strong>iH</strong> system even if you have selected<br />

'run til crash':<br />

• HCDP CURRENT HIGH/LOW (error numbers 310 and 312).<br />

• HCDP THERMISTOR HIGH (error number 512).<br />

• EXHAUST PRESSURE (error number 3912).<br />

On an <strong>iH</strong>600 or <strong>iH</strong>1000 system, the following alarms will cause only the HCMB pump to shut<br />

down, provided 'run til crash' is not selected:<br />

• HCMB POWER HIGH/LOW (error numbers 810 and 812).<br />

• HCMB PHASE IMBALANCE (error number 1012).<br />