Warning message Advisory message Meaning/recommended action<br />

WARNING 3913 The exhaust pressure transducer is not fitted,<br />

or is disconnected or has failed. Check and<br />

rectify as necessary.<br />

WARNING 4009<br />

SS PURGE LOW<br />

WARNING 4010<br />

SS PURGE LOW<br />

WARNING 4011<br />

SS PURGE HIGH<br />

WARNING 4012<br />

SS PURGE HIGH<br />

ADJUST REGULATOR<br />

INCREASE PRESS.<br />

PRESSURE LOW<br />

ADJUST REGULATOR<br />

PRESSURE HIGH<br />

CHECK GAS MODULE<br />

PRESSURE HIGH<br />

CHECK GAS MODULE<br />

The shaft-seals purge pressure is too low.<br />

Check that the nitrogen supply is as specified<br />

in Section 2 and that you have correctly<br />

adjusted the pressure: refer to Section 5.7.<br />

Refer to the recommended actions for error<br />

number 4009 in this table.<br />

The shaft-seals purge pressure is too high.<br />

Check that you have correctly adjusted the<br />

pressure: refer to Section 5.7. If you cannot<br />

correctly adjust the pressure, the regulator may<br />

be faulty.<br />

Refer to the recommended actions for error<br />

number 4011 in this table.<br />

WARNING 4013 The shaft-seals pressure transducer is not<br />

fitted, or is disconnected or has failed. Check<br />

and rectify as necessary.<br />

WARNING 5113 There is a fault in the ADC (analogue-to-digital<br />

convertor) in the Control SMA; the Control<br />

SMA must be replaced.<br />

WARNING 5411<br />

MB TEMP<br />

The temperature of the HCMB pump is too<br />

high. Check the pumping system inlet<br />

pressure; has the pumping system been<br />

operating with inlet pressure > 5 mbar<br />

(5 x 10 2 Pa) for 1 hour or more. If the<br />

maximum inlet pressure has not been<br />

exceeded, or if the pumping system has not<br />

been operated at the maximum inlet pressure<br />

for longer than the specified time, the<br />

cooling-circuit of the pump maybe blocked.<br />

WARNING 5413 Check that the HCMB pump temperature<br />

sensor is fitted and is correctly connected. If<br />

the sensor is correctly fitted and connected, it<br />

may have failed. Check the operation of the<br />

sensor and replace it if it has failed.<br />

WARNING 5511<br />

DP MOTOR TEMP<br />

MOTOR WATER LOW<br />

CHECK WATER<br />

Table 6-1 - Warning messages (continued)<br />

The temperature of the HCDP pump- motor is<br />

too high. Check the cooling-water connections<br />

in the <strong>iH</strong> system and check that the<br />

cooling-water supply is on and is as specified<br />

in Section 2. If the connections and supply are<br />

correct, the cooling-circuit of the pump maybe<br />

blocked.<br />