07.01.2014 Views

CHEM01200604004 Shri Sanyasinaidu Boddu - Homi Bhabha ...

CHEM01200604004 Shri Sanyasinaidu Boddu - Homi Bhabha ...

CHEM01200604004 Shri Sanyasinaidu Boddu - Homi Bhabha ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

chemical shift anisotropy is much higher and the value significantly increases with increase<br />

in Eu 3+ content in the sample (viz. Table 6). Comparable values of chemical shift anisotropy<br />

for both GaPO 4 and 2.5 at % Eu 3+ incorporated GaPO4 nanoparticles, further confirm the<br />

absence of P-O-Eu 3+ linkages in the sample. In other words Eu 3+ ions are not in the near<br />

vicinity of P and must be in the vicinity of Ga 3+ ions, as Ga-O-Eu linkages formed by<br />

undergoing surface ion exchange with protons of the Ga-OH linkages. For GaPO 4<br />

nanoparticles with higher Eu 3+ concentrations (5 at % and more), there is an increase in<br />

fluctuating magnetic field created around P by paramagnetic EuPO 4 nanoparticles. Similar<br />

increase in the side band intensities and anisotropy values are also observed in 29 Si and<br />

27 Al MAS NMR patterns of alumino silicates containing paramagnetic iron compounds [238,<br />

239]. A schematic diagram showing the ion exchange process leading to the formation of Ga-<br />

O-Eu linkages is shown in Fig.59. No separate peaks corresponding to EuPO 4 phase is seen<br />

in the XRD patterns for sample corresponding to more than 2.5 atom % Eu 3+ . This is because<br />

of its relatively smaller concentration and poor crystallinity associated with its nanophase<br />

nature.<br />

Table 6. The anisotropy parameter (∆δ) obtained form the components of the chemical shift<br />

tensor (δ 11 , δ 22 and δ 33 ) which are calculated from the side band intensities<br />

observed form the 31 P MAS NMR patterns of GaPO 4 sample containing different<br />

amounts of Eu 3+ ions. The line width of the peak (Γ) is also given in the table. Error<br />

in the chemical shift values is ±1 ppm.<br />

Structural Value Value Value Value Value Value of ∆δ<br />

Configuration of 31 P of δiso of Γ of δ11 of δ22 of δ33<br />

(ppm)<br />

(ppm) (Hz) (ppm) (ppm) (ppm) |δ 33 -δ 11 |<br />

GaPO -10 344 2 -14 -18 20<br />

4<br />

GaPO4<br />

-10.3 472 7 -17 -20 27<br />

3+<br />

with 2.5 at % Eu<br />

GaPO 4<br />

3+<br />

with 5 at % Eu -10.3 516 21 -23 -29 50<br />

GaPO 4<br />

3+<br />

with 10 at % Eu -10.3 626 29 -24 -36 65<br />

111

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!