4. ANN based Current Controllers (CC)<br />
Variable switching frequency controllers<br />
Among the main advantages of hysteresis CC are: simplicity, outstanding<br />
robustness, lack of tracking errors, independence of load parameter changes, and<br />
extremely good dynamics limited only by switching speed and load time constant.<br />
However, this class of schemes, also known as free-running hysteresis controllers<br />
[16], has the following disadvantages:<br />
- the converter switching frequency depends largely on the load parameters and varies<br />
with the AC voltage,<br />
- the operation is somewhat rough due to the inherent randomness caused by the<br />
limit cycle; therefore, protection of the converter is difficult [56].<br />
It is characteristic of the hysteresis CC that the instantaneous current is kept exact in a<br />
tolerance band except for systems without neutral leaders where the instantaneous<br />
error can reach double the value of the hysteresis band [3,54]. This is due to the<br />
interaction in the system with three independent controllers. The change of<br />
comparator state in one-phase influences the voltage applied to the load in two other<br />
phases (coupling). However, if all three current errors are considered as space vectors<br />
[60], the interaction effect can be compensated, and many variants of controllers<br />
known as space vector based, can be created [41,48,50,58, 63,68]. Moreover, if threelevel<br />
comparators with a look-up table are used, a considerable decrease in the<br />
inverter switching frequency can be achieved [37,48,50,58,63]. This is possible<br />
thanks to appropriate selection of zero voltage vectors [48] (Fig.4.2c).<br />
In the synchronous rotating d-q coordinates, the error field is rectangular and the controller<br />
offers the opportunity of independent harmonic selection by choosing different<br />
hysteresis values for the d and q components [49,62]. This can be used for torque<br />
ripple minimisation in vector controlled AC motor drives (the hysteresis band for the<br />
torque current component is set narrower than that for flux current component).<br />
Constant average switching frequency controllers<br />
A number of proposals have been put forward to overcome variable switching<br />
frequency. The tolerance band amplitude can be varied, according to the AC side<br />
voltage [39,43,47,53-55,57,59,69,103], or by means of a PLL control (Fig.8).<br />
An approach which eliminates the interference, and its consequences, is that of<br />
decoupling error signals by subtracting an interference signal derived from the mean<br />
inverter voltage u N (Fig.4.3) [54]. Similar results are obtained in the case of<br />
44