4. ANN based Current Controllers<br />

not going to zero vector the Pulse Polarity Consistency Rules (PPCR) is violated. To<br />

eliminate these disadvantages and force the NN regulator to select zero vectors and<br />

only adjacent active vectors a modified sampling technique is proposed (Fig. 4.12.).<br />

a)<br />

ε A<br />

K<br />

S&H<br />

S A<br />

ε B<br />

K<br />

S&H<br />

S B<br />

ε C<br />

K<br />

S&H<br />

S C<br />

b)<br />

SH A SH B<br />

SH<br />

C<br />

Fig. 4.12. Improved NN regulator : a) block scheme, b) modified sampling technique<br />

When the sign of the NN outputs signals are sampled not at the same instant but with<br />

a phase shift (Fig. 4.12b) i.e.2π/3, the regulator output signals S A<br />

,S B<br />

,S C<br />

can have the<br />

same values. The inverter under such control operates as shown in Table 4.4. and<br />

illustrates in Fig. 4.14.<br />