08.03.2014 Views

Laboratory Product Catalogue Total Laboratory Science Support

Laboratory Product Catalogue Total Laboratory Science Support

Laboratory Product Catalogue Total Laboratory Science Support

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Sartocon ® Slice 200. The Low Hold-Up Volume<br />

Crossflow Cassette Filter for Low Volume Applications<br />

Ultrafiltration and Cell Harvesting Filtration<br />

Sartocon Slice 200<br />

Sartocon Slice 200 Crossflow filters are<br />

designed for low volume applications.<br />

Target use<br />

– product discovery<br />

– pre-clinical trials<br />

– small-scale clinical trials<br />

– membrane screening<br />

The cassettes are available with Polyethersulfone<br />

and Hydrosart membrane types in<br />

both MF and UF formats.<br />

The Polyethersulfone membrane<br />

The robust polyethersulfone membrane<br />

(PESU) is a polymer –which is stable within<br />

a broad pH (1–14) and temperature range –<br />

that is well established and widely accepted<br />

in the biotechnological and pharmaceutical<br />

industries. Membrane regeneration and<br />

depyrogenation is accomplished by using<br />

(1N) NaOH at elevated temperatures as<br />

required. Cassettes are stored in 0.1N NaOH.<br />

The Hydrosart ® membrane<br />

Hydrosart is a stabilized cellulose-based<br />

membrane that has been optimized for use<br />

in the biotechnological and pharmaceutical<br />

industries. The Hydrosart membrane is a stable<br />

polymer (created by a Sartorius patented<br />

process) which is compatible with a wide<br />

range of chemical agents and stable within<br />

a broad pH range. It is also an extremely<br />

hydrophilic and neutral membrane, making<br />

it non-protein binding and virtually nonfouling.<br />

It exhibits extremely high and<br />

consistent flux rates. Membrane regeneration,<br />

and depyrogenation is accomplished by using<br />

(1N) NaOH at elevated temperatures as<br />

required. Cassettes are stored in 0.1N NaOH.<br />

<strong>Product</strong> profile<br />

Hydrosart cassettes exhibit no adsorption of<br />

proteins, viruses, etc. Membrane retention is<br />

unaffected by repeated use. The Hydrosart<br />

ultrafiltration cassette can be re-used without<br />

any loss of integrity or performance.<br />

“Out-of-the-box” performance is maintained<br />

with multiple uses. These features make the<br />

PESU and Hydrosart membrane ideally suited<br />

to the biotechnological industry.<br />

Feature<br />

Benefits<br />

Low hold-up volume Minimized working<br />

volume.<br />

Low protein-binding High product yield;<br />

Easily cleaned.<br />

Wide pH and a wide Chemicals can be<br />

variety of temperature used for the removal<br />

range<br />

of foulants.<br />

High flow rates Economical filtration<br />

runs.<br />

Silicone sealing No glues etc.<br />

compound<br />

Self Sealing.<br />

Identical flow geome- Straight line,<br />

try and hydraulic scale-up.<br />

dimensions as larger<br />

scale-up devices.<br />

Ordering information<br />

Available Slice 200 types and order numbers<br />

Cut off | Pore size Hydrosart Polyethersulfone<br />

200 cm 2 filter area 200 cm 2 filter area<br />

1 kD 3081460902E--SG<br />

2 kD 3081441902E--SG<br />

5 kD 3081442902E—SG 3081462902E--SG<br />

8 kD 3081463402E--SG<br />

10 kD 3081443902E--SG 3081463902E--SG<br />

30 kD 3081445902E--SG 3081465902E--SG<br />

50 kD 3081465002E--SG<br />

100 kD 3081446802E--SG 3081466802E--SG<br />

300 kD 3081467902E--SG<br />

0.1 µm 3081545802W--SG<br />

0.2 µm 3081860702W--SG<br />

0.45 µm 3081860602W--SG<br />