MD8 airscan ® Air Sampler for Critical Applications<br />
Air Monitoring | MD8 airscan ® Microbiological<br />
Analysis<br />
The system consists of the MD8 airscan air<br />
sampler and disposable gelatine filter units.<br />
The system is routinely used for the quantitative<br />
detection of air-borne organisms, mainly<br />
at filling lines in sterile areas of class A<br />
(classification according to “EU Guide for<br />
GMP”), isolators, or blow-fill-seal machines.<br />
The exceptionally high air flow rate of 8 m 3 /h<br />
enables isokinetic sampling at flow rates that<br />
are usual in laminar flow as well as filtration<br />
of 1 m 3 air very quickly (less than 8 minutes).<br />
The filter unit can be placed separately from<br />
the air sampler for remote sampling.<br />
Specifications for the MD8 airscan air sampler<br />
Air flow rate<br />
Timer<br />
Max. deviation<br />
Noise level<br />
Weight<br />
Dimensions (L+W+H)<br />
Correction of the air flow<br />
rate setting<br />
2.0 m 3 /h – 8 m 3 /h adjustable in 100-liter steps<br />
1–99 minutes, adjustable in 1-minute steps<br />
±5% in a temperature range of 15°–35°C<br />
For gelatine membrane filters, max. 62 dB (A)<br />
Approx. 6.5 kg<br />
375+242+228 mm<br />
The MD8 airscan air sampler allows to adjust<br />
selectively and easily air flow rate and sample<br />
removal speed. By means of a specially developed<br />
calibration unit (see accessories), the<br />
user can calibrate the MD8 airscan locally,<br />
e.g. within the scope of validation steps.<br />
After removing the sample, the gelatine filter<br />
can be placed directly on the agar culture<br />
medium for incubation and colony growth.<br />
When the entered air flow rate cannot be attained,<br />
the display shows the max. attainable flow rate for<br />
a corresponding new setting below this value.<br />
Ordering information for the MD8 airscan air sampler<br />
Order number<br />
16746 MD8 airscan air sampler, 230 V, 50 Hz<br />
16747 MD8 airscan air sampler, 115 V, 60 Hz<br />
16748 MD8 airscan air sampler, 100 V, 50–60 Hz<br />
Each version can be switched from 50 to 60 Hz and back.<br />
Accessories for the MD8 airscan air sampler<br />
Order number<br />
17801 Holder for disposable gelatine filter units<br />
Ordering information for consumables<br />
Disposable gelatine units, sterile, pack of 10<br />
Order number<br />
17528--80----ACD<br />
17528--80----BZD<br />
17528--80----VPD<br />
Individually packed in 1 polyethylene bag each<br />
Individually packed in 3 polyethylene bags each<br />
Individually packed in 3 polyethylene bags each,<br />
but label on innermost bag<br />
Special brochures available on request. Order no. SLF3001-e|SM-3011-e<br />