straight l<strong>in</strong>e per log cycle and the pump<strong>in</strong>g rate were<br />

substituted <strong>in</strong>to equation 5 and the coefficient of transmissibility<br />

was computed to be 95,600 gpd/ft. The slope<br />

of the straight l<strong>in</strong>e per log cycle from distance-drawdown<br />

data on a l<strong>in</strong>e perpendicular to the river and on a<br />

l<strong>in</strong>e parallel to the river are approximately the same<br />

suggest<strong>in</strong>g that the effects of <strong>in</strong>duced <strong>in</strong>filtration on<br />

drawdowns were negligible. The coefficient of storage, S,<br />

was computed from the follow<strong>in</strong>g equation (Cooper and<br />

Jacob, 1946):<br />

where:<br />

(7)<br />

Figure 16. Distance-drawdown data for aquifer test 4<br />

Figure 17. Location of wells used <strong>in</strong> aquifer test 5<br />

The pumped well was 12 <strong>in</strong>ches <strong>in</strong> diameter and 88<br />

feet deep; the lower 10 feet of the well was screened.<br />

Observation wells AS-1, AS-2, AN-1, AW-1, AW-2, and<br />

AE-1 were 6 <strong>in</strong>ches <strong>in</strong> diameter and averaged about 90<br />

feet <strong>in</strong> depth. Well AE-3 was 6 <strong>in</strong>ches <strong>in</strong> diameter and<br />

124 feet <strong>in</strong> depth. Drillers logs of wells are given <strong>in</strong> table<br />

12. Record<strong>in</strong>g gages were <strong>in</strong>stalled on the observation<br />

wells and the Mississippi River. Values of drawdown <strong>in</strong><br />

wells AS-1, AW-1, AE-1, AS-2, AS-3, and AW-2 at a<br />

time 1830 m<strong>in</strong>utes after pump<strong>in</strong>g started were plotted<br />

on semilogarithmic paper aga<strong>in</strong>st values of distances<br />

from the pumped well as shown <strong>in</strong> figure 18. A straight<br />

l<strong>in</strong>e was drawn through the po<strong>in</strong>ts. The slope of the<br />

The coefficient of storage (0.135) is <strong>in</strong> the <strong>water</strong>-table<br />

range.<br />

The distance a was found to be 100 feet from the<br />

river's edge, as determ<strong>in</strong>ed from <strong>water</strong>-level data collected<br />

dur<strong>in</strong>g a production test February 13-19, 1959,<br />

us<strong>in</strong>g the collector well constructed at the site of aquifer<br />

test 5, hydraulic properties of the aquifer determ<strong>in</strong>ed<br />

from the aquifer test May 29 - June 1, 1956, and equation<br />

6. Pump<strong>in</strong>g from the collector well was started at 8 a.m.<br />

on February 13 and cont<strong>in</strong>ued at a constant rate of 7000<br />

gpm until 3:15 p.m. February 17 when the pump<strong>in</strong>g rate<br />

was <strong>in</strong>creased to 8400 gpm. The pump<strong>in</strong>g test cont<strong>in</strong>ued<br />

at a rate of 8400 gpm until 8:15 p.m. February 19 when<br />

pump<strong>in</strong>g was stopped and <strong>water</strong> levels were allowed to<br />

recover. Record<strong>in</strong>g gages were <strong>in</strong>stalled on observation<br />

wells AS-3, AE-1, and AN-1. Frequent <strong>water</strong>-level measurements<br />

were made with a steel tape <strong>in</strong> well AS-2. In<br />

addition, record<strong>in</strong>g gages were <strong>in</strong>stalled on the Mississippi<br />

River, on the collector well, and on an observation<br />

well immediately outside the collector well.<br />

An aquifer test (test 6) was made August 4-8, 1952,<br />

by Ranney Method Water Supplies, Inc., for the Monsanto<br />

Chemical Corporation. The test site is located east<br />

of Monsanto, along the Mississippi River <strong>in</strong> sec. 27,<br />

T2N, R10W. Seven wells, grouped as shown <strong>in</strong> figure 19<br />

were used. The wells were arranged <strong>in</strong> a ‘T’ pattern with<br />

four wells parallel to and 515 feet east of the Mississippi<br />

River and three wells perpendicular to the river. Pump<strong>in</strong>g<br />

was started at 6 p.m. August 4 and was cont<strong>in</strong>ued at<br />

a constant rate of 1100 gpm until 6 p.m. August 8 when<br />

pump<strong>in</strong>g was stopped and <strong>water</strong> levels were allowed to<br />

recover.<br />

Observation wells S-1, W-1, N-1, S-2, W-2, and W-3<br />

were 7 <strong>in</strong>ches <strong>in</strong> diameter and were drilled to depths of<br />

about 100 feet. The pumped well was 12 <strong>in</strong>ches <strong>in</strong> diameter<br />

and was drilled to a depth of 99 feet; 10 feet of screen<br />

was <strong>in</strong>stalled at the bottom. Available logs of wells are<br />

given <strong>in</strong> table 13. Record<strong>in</strong>g gages were <strong>in</strong>stalled on the<br />