23.03.2014 Views

download - Knoll

download - Knoll

download - Knoll

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Panel Specifications<br />

Dividends Horizon<br />

Post Connectors<br />

<br />

‘‘X’’ configurations. For same-height applications,<br />

post connectors are available as an assembly<br />

and include the post, vertical trim and top cap.<br />

For high-low panel-to-post applications, post<br />

connectors are specified by component.<br />

Post and Post Component Construction<br />

<br />

<br />

<br />

powder coat finish<br />

<br />

molded plastic<br />

Attachment: Post connectors use the universal<br />

panel connection hardware from adjacent panels<br />

Electrical and data access: Posts<br />

have cut-outs that match the wire and<br />

cable access channels provided by panel<br />

frames. This allows wire conduits and data<br />

cables to be routed through the post at<br />

the topway, beltway and base raceway.<br />

Electrical and Communications<br />

Dividends Horizon provides a logical<br />

approach for planning and installing electrical<br />

systems and communication cables.<br />

Power is installed along the base raceway<br />

with access available in both the base<br />

raceway and optional beltway.<br />

Topway Panel Frame Electrical<br />

Allows data cables to be routed horizontally<br />

and vertically within the panel.<br />

<br />

Cables can be routed along the tops of panels,<br />

routed through the interior of panels and<br />

along both the beltway and base raceway.<br />

The primary channel for distributing cable is<br />

provided in the horizontal topway along the<br />

top of panels. The topway allows cables to<br />

be easily laid-in during initial installation and<br />

<br />

also separates data from power to reduce the<br />

chance of interference. A vertical wire pathway is<br />

provided in the center of the topway. This allows<br />

cables to be run vertically through the interior<br />

of the panel to the beltway or base raceway<br />

without the use of exterior cable managers.<br />

Topway<br />

Data Cabling Bend Radius<br />

Base raceway<br />

Topway Panel Frame Trough<br />

Min. bend radius 1 1 / 2"<br />

Max. bend radius 3"<br />

Min. bend radius 1 1 / 2"<br />

Max. bend radius 6"<br />

Topway<br />

"L" Post Connection<br />

"L" Post Cover Attachment<br />

Topway Panel Frame<br />

Cable Routing<br />

Vertical<br />

wire pathway<br />

Two-way<br />

Top Cap<br />

Beltway<br />

Universal<br />

Post<br />

Corner Post Cover<br />

Base<br />

raceway<br />

10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!