Electrical Infeeds and Power Poles<br />
Specifications<br />
Dividends Horizon<br />
Power Infeeds<br />
<br />
<br />
base raceway. Two styles are available:<br />
<br />
<br />
Base Power Infeed<br />
Dividends Horizon base power infeeds route<br />
power from floor monuments or electrical boxes<br />
to any terminal block duplex position on base<br />
raceway power modules. Two screws secure<br />
the base power infeed to the power module.<br />
Note: When connected, a base power infeed<br />
takes the place of one duplex outlet.<br />
Base power infeeds have a 56" long liquid<br />
tight conduit and pigtail for connection<br />
<br />
Infeeds are specified either right- or left-handed.<br />
This allows the conduit to enter the outlet<br />
position from either the left or right side.<br />
In addition to right- or left handed base<br />
power infeeds is a reversible base power<br />
infeed with a 56" long liquid tight conduit.<br />
The reversible infeed rotates to provide<br />
either a right- or left-hand power entry.<br />
Specify the base infeed that matches the<br />
power system accessed and left or right<br />
cable entry (example: (3+1), left-hand entry).<br />
Ceiling Infeeds<br />
Raceway-to-ceiling infeeds route power from<br />
a ceiling-located power source to the panel<br />
<br />
which plug into any terminal block outlet<br />
position, ceiling infeeds must plug into the end of<br />
a base raceway power module. Ceiling infeeds<br />
have a 19 1 / 2' long metal conduit and pigtail.<br />
Two components are required for installation:<br />
<br />
<br />
Ceiling infeed may be installed directly into a<br />
beltway power module for beltway electrical only.<br />
Specify the ceiling infeed that matches<br />
the power system accessed.<br />
Power Poles<br />
Power poles can accommodate one racewayto-ceiling<br />
infeed along with data cables. The<br />
power pole can also be used to route data<br />
cables only, if required. Cable capacity for<br />
power poles with the electrical conduit installed<br />
is 30, category 5 cables and without an<br />
electrical conduit is 40, category 5 cables.<br />
Power poles integrate within the panel system<br />
footprint by mounting atop existing post<br />
<br />
Power poles are available in three lengths in<br />
order to accommodate all three heights of<br />
post connectors. All power poles measure<br />
126" or 144" when added to the height of<br />
the post connector. For ceilings less than<br />
126" or 144" high, field-cut the power pole<br />
to the required height. Power poles include<br />
ceiling trim plate, connecting hardware<br />
and post/power pole trim covers.<br />
Legacy Power Pole Construction<br />
Power pole is extruded aluminum powder<br />
coated, with four PVC trim covers.<br />
Dividends Horizon DP7 Power Pole<br />
Construction<br />
Power pole is extruded aluminum, with<br />
removable cover, powder coated in any<br />
<strong>Knoll</strong> Core or Dividends Horizon Legacy<br />
finish. One side of the power pole is<br />
open, allowing cables to be inserted or<br />
removed when the cover is removed.<br />
CAUTION: DO NOT CONNECT POWER<br />
UNTIL INSTALLATION IS COMPLETE.<br />
CONNECTION TO BUILDING POWER<br />
SOURCE MUST BE PERFORMED<br />
BY A LICENSED ELECTRICIAN.<br />
Ceiling Connection<br />
Ceiling Infeed Connection<br />
Ceiling<br />
Connection<br />
Ceiling Infeed,<br />
Ceiling Connection<br />
Power Pole<br />
Power Infeeds<br />
Power Pole<br />
Connection<br />
Base Power Infeed<br />
(right infeed shown)<br />
Ceiling Infeed<br />
Base Raceway<br />
Connection<br />
Ceiling Infeed<br />
Base Raceway<br />
Connection<br />
Base Raceway<br />
Infeed Connection<br />
(right infeed shown)<br />
Reversible Base<br />
Power Infeed<br />
198