Electrical Specifications<br />

(3+1) Electrical System<br />

Dividends Horizon<br />

3+1 Circuit Electrical<br />

The Dividends Horizon 3+1 electrical system<br />

is designed for areas where power usage is<br />

<br />

<br />

The wire configuration of the 8-wire/4<br />

circuit electrical system is (see chart):<br />

<br />

<br />

<br />

<br />

for circuits #1, 2 and 3<br />

<br />

for circuits #1, 2 and 3<br />

<br />

<br />

<br />

yellow) for circuit 4<br />

Circuits 1, 2 and 3 have shared neutral and<br />

grounds for convenience power while circuit<br />

4 has a separate ground and neutral for<br />

designated/isolated power or to support<br />

uninterrupted power supply (UPS).<br />

Compatibility<br />

All Dividends Horizon power systems<br />

use components that appear similar.<br />

However, components from the three<br />

different power systems are not functionally,<br />

fully interchangeable. 3+1 components<br />

can be connected to 3+3 wire systems,<br />

however only 3+1 will function.<br />

Wiring Diagram (3+1)<br />

Circuits<br />

1 2 3 4<br />

Wires<br />

3+1 Duplex Receptacles<br />

Duplex receptacles used in 3+1<br />

electrical systems are:<br />

<br />

1(pattern number DE1DR1)<br />

<br />

2 (pattern number DE1DR2)<br />

<br />

3 (pattern number DE1DR3)<br />

<br />

(pattern number DE1DR4)<br />

Isolated duplex receptacle number 4<br />

has an orange-colored triangle on black<br />

background to identify an isolated duplex.<br />

An optional orange-colored isolated<br />

duplex is also available. It has the isolated<br />

identifying triangle outlined in black.<br />

<br />

number 4 (pattern number DE1DOR4)<br />

3+1 Electrical System Technical<br />

Specifications<br />

The 3+1 electrical system consists of<br />

four 20 amp, 120 volt, 60-Hertz circuits.<br />

The circuits will accommodate 120 volt<br />

single phase, 120/240 volt split phase and<br />

120/208 volt three phase power. System<br />

components are 20 amp capacity. The<br />

National Electric Code (NEC) limits continuous<br />

loads to 80% of capacity or 16 amps.<br />

Wires<br />

Typically, each circuit can power 8-10 duplex<br />

convenience outlets with normal loads. In<br />

heavier load situations, such as computer<br />

systems, each circuit will power 3-5 duplex<br />

outlets. If each workstation has two convenience<br />

duplex outlets and one protected duplex, the<br />

8-wire (4-circuit) system can supply a cluster<br />

of 6 -10 workstations from each infeed.<br />

Surge Suppressors<br />

Dividends Horizon surge suppressors<br />

(pattern number DE1SS) plug into any<br />

terminal block position to provide surge<br />

protection for all duplexes on that circuit.<br />

Note: When connected, surge suppressors take<br />

the place of a duplex receptacle resulting in the<br />

elimination of one duplex position from the circuit.<br />

Independent Neutral Electrical Systems<br />

Dividends Horizon offers a 2+1 electrical system<br />

with independent neutrals as a standard special.<br />

It is our belief that independent neutrals are<br />

<br />

an independent neutral electrical system, a<br />

Dividends Horizon solution can be provided. For<br />

further information, list pricing and schematic<br />

drawings, contact <strong>Knoll</strong> Customer Service.<br />

SPECIFYING ELECTRICAL COMPONENTS<br />

Panel Power Module<br />

Specify one panel power module per<br />

panel that matches the width of the panel<br />

<br />

Power Connector<br />

Specify one power connector (with or<br />

without post) to connect panel power<br />

modules in adjacent panels.<br />

Power Jumper<br />

Specify one power jumper that matches<br />

the width of the panel(s) being passed<br />

through to connect to panel power<br />

modules in nonadjacent panels.<br />

Black<br />

A<br />

Red<br />

B<br />

Blue<br />

C<br />

X<br />

Pink<br />

White/<br />

Black<br />

N1<br />

N2<br />

White/<br />

Red<br />

Green<br />

G1<br />

G2<br />

Green/<br />

Yellow<br />

178