Water Sensitive Urban Design<br />
Functional and hydraulic functions<br />
Inlet and outlet pipes and headwalls<br />
correctly set out and at correct level<br />
(upstream and downstream ends)<br />
Bypass weir correct width and level<br />
Overflow pit is correct size and crest is<br />
at correct level<br />
Bypass weir correct width and level<br />
<strong>Maintenance</strong> pipe and valve installed<br />
at correct location and level<br />
<strong>Maintenance</strong> access installed to basin<br />
Rock protection provided at correct locations and<br />
rock size consistent with design (applicable to<br />
sediment basin, only)<br />
Hold Point - Sign off is required from superintendent and wetland designer before proceeding<br />
Comments<br />
Signed by Superintendent(s):<br />