February 1999 Rev. 1.2 Communication Reader-Host<br />

3.7.18 HT2_Get_Snr_Reset<br />

This command is applied to a HITAG 2 transponder which is currently not in Password or<br />

Crypto Mode but in one of the Public Modes. The command selects the transponder and provides<br />

its serial number and Configuration Byte.<br />

If the byte -Status- shows „no error“ the transponder is selected and ready for read or write<br />

accesses.<br />

The byte -mode- decides whether the selection process for the transponder is done corresponding<br />

to the Password Mode or the Crypto Mode.<br />

C-Function: void HT2_Get_Snr_Reset (BYTE_T mode, DWORD_T *snr,<br />

BYTE_T *config);<br />

Header-File: Hitag2.H<br />

Serial protocol:<br />

HOST - READ/WRITE DEVICE<br />

0x03 0x80 mode ‘M’ BCC<br />

mode:<br />

0x00 ... Password<br />

0x01 ... Crypto<br />

READ/WRITE DEVICE - HOST<br />

7 0 ------ 31 24<br />

n+2 Status SNR-LSB ------ SNR-MSB config BCC<br />

config: Configuration Byte of HITAG 2<br />

n = 0 if an error occurred (error code in Status).<br />

n = 5 if data were read from a transponder (Status = 0).<br />

Status: 0 ... no error<br />

-1 ... SERIAL ERROR<br />

-3 ... NOTAG<br />

-5 ... INCORRECT PASSWORD RWD<br />

-6 ... INCORRECT PASSWORD TAG<br />

-7 ... AUTHENTICATION ERROR<br />

Page 33 (107)<br />

Protokoll HTRM801 V1.2/C