February 1999 Rev. 1.2 Communication Reader-Host<br />
3.7.18 HT2_Get_Snr_Reset<br />
This command is applied to a HITAG 2 transponder which is currently not in Password or<br />
Crypto Mode but in one of the Public Modes. The command selects the transponder and provides<br />
its serial number and Configuration Byte.<br />
If the byte -Status- shows „no error“ the transponder is selected and ready for read or write<br />
accesses.<br />
The byte -mode- decides whether the selection process for the transponder is done corresponding<br />
to the Password Mode or the Crypto Mode.<br />
C-Function: void HT2_Get_Snr_Reset (BYTE_T mode, DWORD_T *snr,<br />
BYTE_T *config);<br />
Header-File: Hitag2.H<br />
Serial protocol:<br />
HOST - READ/WRITE DEVICE<br />
0x03 0x80 mode ‘M’ BCC<br />
mode:<br />
0x00 ... Password<br />
0x01 ... Crypto<br />
READ/WRITE DEVICE - HOST<br />
7 0 ------ 31 24<br />
n+2 Status SNR-LSB ------ SNR-MSB config BCC<br />
config: Configuration Byte of HITAG 2<br />
n = 0 if an error occurred (error code in Status).<br />
n = 5 if data were read from a transponder (Status = 0).<br />
Status: 0 ... no error<br />
-1 ... SERIAL ERROR<br />
-3 ... NOTAG<br />
-5 ... INCORRECT PASSWORD RWD<br />
-6 ... INCORRECT PASSWORD TAG<br />
-7 ... AUTHENTICATION ERROR<br />
Page 33 (107)<br />
Protokoll HTRM801 V1.2/C