11.06.2014 Views

TAGnology_TAGid -125kHz_Protocol.pdf - RFID Webshop

TAGnology_TAGid -125kHz_Protocol.pdf - RFID Webshop

TAGnology_TAGid -125kHz_Protocol.pdf - RFID Webshop

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Communication Reader-Host Rev. 1.2 February 1999<br />

3.8.6 KI_Write_Control<br />

This command writes a new value to the control bytes Control_RW and Control_WO into the<br />

EEPROM of the read/write device.<br />

Initial values stored in the EEPROM of a delivered read/write device:<br />

Control_RW = 0x7F<br />

Control_WO = 0xFF<br />

ATTENTION: Once a bit in Control_RW or Control_WO has been set to ‘0’ it is<br />

impossible to change it back to one. We strongly recommend to read Chapter<br />

„Personalization“ carefully before using this command.<br />

C-Function: void KI_Write_Control (BYTE_T control_rw, BYTE_T control_wo);<br />

Header-File: HitagKeyInit. H<br />

Serial protocol:<br />

HOST - READ/WRITE DEVICE<br />

0x04 'c' Control_RW Control_WO BCC<br />

Control_RW: see Chapter „Personalization“<br />

Control_WO: see Chapter „Personalization“<br />

READ/WRITE DEVICE - HOST<br />

0x02 Status<br />

Status:<br />

BCC<br />

0 ... no error<br />

- 1 ... SERIAL ERROR (in this case the error can also mean, that the read/write<br />

device is not in the KeyInit Mode!)<br />

Protokoll HTRM801 V1.2/C Page 70 (107)