February 1999 Rev. 1.2 Communication Reader-Host<br />

If polling for HITAG 1 Advanced <strong>Protocol</strong> Mode was successful:<br />

7 0 ------ 31 24<br />

0x08 Status 0x80 SNR-LSB ------ SNR-MSB more BCC<br />

more: Proximity Reader: more is always 0.<br />

Long Range Reader: more equal to one indicates that there is at least one additional<br />

transponder in the reading area of the read/write device.<br />

If polling for Miro / HITAG 2 Public Mode A was successful:<br />

0x08 Status 0x02 data[0] ----- data[4] BCC<br />

If polling for HitagS Crypto was successful:<br />

7 0 ------ 31 24<br />

0x08 Status 0x80 SNR-LSB ------ SNR-MSB more BCC<br />

If polling for HITAG 2 Password Mode was successful:<br />

7 0 ------ 31 24<br />

0x08 Status 0x08 SNR-LSB ------ SNR-MSB config BCC<br />

If polling for HITAG 2 Crypto Mode was successful:<br />

7 0 ------ 31 24<br />

0x08 Status 0x10 SNR-LSB ------ SNR-MSB config BCC<br />

If polling for HitagS Advanced <strong>Protocol</strong> Mode was successful:<br />

7 0 ------ 31 24<br />

0x08 Status 0x80 SNR-LSB ------ SNR-MSB more BCC<br />

If polling for HITAG 2 Public Mode B was successful:<br />

0x13 Status 0x40 data[0] ----- data[15] BCC<br />

Status: 0 ... no error<br />

-1 ... SERIAL ERROR<br />

Page 41 (107)<br />