Communication Reader-Host Rev. 1.2 February 1999<br />

3.9.2 Proximity/Long Range: READ PLAIN<br />

GetSnr<br />

SelectSnr<br />

Read (Plain)<br />

HaltSelected<br />

Reads the serial number of a transponder in the communication<br />

field of the antenna.<br />

Use C-Function proloc_GetSnr or proloc_GetSnr_Adv.<br />

Selects (prepares) the transponder for a following read process.<br />

Use C-Function proloc_SelectSnr or proloc_SelectLast.<br />

Reads a transponder.<br />

Use C-Function proloc_ReadPage or proloc_ReadBlock.<br />

Mutes the just treated transponder.<br />

3.9.3 Proximity/Long Range: WRITE PLAIN<br />

GetSnr<br />

SelectSnr<br />

Write (Plain)<br />

Read (Plain)<br />

HaltSelected<br />

Writes data to a transponder.<br />

Use C-Function proloc_WritePage or proloc_WriteBlock.<br />

To substantially increase the data reliability we strictly recommend<br />

to read the previously written data (read after write).<br />

Use C-Function proloc_ReadPage or proloc_ReadBlock.<br />

Mutes the just treated transponder.<br />