Communication Reader-Host Rev. 1.2 February 1999<br />

3.7.49 RWD_Key_Init_Mode<br />

To be able to personalize the read/write device it is necessary to enter a special mode, the<br />

KeyInit Mode.<br />

The password (is different from Keys or Logdata) ensures that none but authorized persons are<br />

able to enter the KeyInitMode.<br />

ATTENTION: After the successful execution of this command (answer sent with<br />

Operating Mode BCC calculation) the read/write device enters the KeyInit Mode and BCC<br />

calculation changes.<br />

The read/write device changes BCC calculation automatically. On the host system the user is<br />

responsible for the new BCC calculation. The C-Library provides the function<br />

proloc_SetBCCMode ( ).<br />

C-Function: void RWD_Key_Init_Mode (DWORD_T password);<br />

Header-File: HitagRWD . H<br />

Serial protocol:<br />

HOST - READ/WRITE DEVICE<br />

7 0 15 8 23 16 31 24<br />

0x06 'K' PW0 PW1 PW2 PW3 BCC<br />

//<br />

READ/WRITE DEVICE - HOST<br />

0x02 Status BCC<br />

Status:<br />

0 ... no error<br />

-1 ... SERIAL ERROR<br />

-11 ... EEPROM WRONG OLD DATA<br />

The password was incorrect. The read/write device remains in Operating<br />

Mode.<br />

Protokoll HTRM801 V1.2/C Page 64 (107)