February 1999 Rev. 1.2 Communication Reader-Host<br />

3.7.34 RWD_Read_Ports<br />

This command reads the status of those port Pins of the HITAG Communication Controller<br />

(Port 0) that are configured as inputs.<br />

ATTENTION: To use commands referring to Port 0 you need a special hardware with<br />

connected Port 0 signals is required (Port 0 signals are not available on pin connectors of<br />

Philips Core Modules).<br />

Bit-positions of output-configured pins are read as ‘0’.<br />

C-Function: void RWD_Read_Ports (BYTE_T *input);<br />

Header-File: HitagRWD.H<br />

Serial protocol:<br />

HOST - READ/WRITE DEVICE<br />

0x02 'i' BCC<br />

READ/WRITE DEVICE - HOST<br />

0x03 Status input BCC<br />

input:<br />

7 6 5 4 3 2 1 0<br />

P0.7 P0.6 P0.5 P0.4 P0.3 P0.2 P0.1 P0.0<br />

0 ... reset (0 V)<br />

1 ... set (5 V)<br />

Status: 0 ... no error<br />

-1 ... SERIAL ERROR<br />

Page 51 (107)<br />