February 1999 Rev. 1.2 Communication Reader-Host<br />

3.7.43 RWD_Set_BCD<br />

This Long Range Reader command effects that a new BCD (BitClockDelay) value is passed to<br />

the DSP (Digital Signal Processor) and written into the EEPROM of the read/write device. This<br />

value adjusts the timing of the read/write device in accordance to the connected antenna.<br />

A new adjustment may be necessary whenever a new type of antenna is connected to the<br />

read/write device.<br />

Bits 4-7 of -bitclockdata- represent the BCD value. If Bit 3 of -bitclockdata- is set to 0, a FFT<br />

(Fast Fourier Transformation) of the DSP with the new BCD value is started in addition.<br />

Standard value stored in the EEPROM:<br />

bitclockdata = 0x90<br />

C-Function: void RWD_Set_BCD (BYTE_T bitclockdata);<br />

Header-File: HitagRWD.H<br />

Serial protocol:<br />

HOST - READ/WRITE DEVICE<br />

0x03 'F' Bitclockdata BCC<br />

bitclockdata:<br />

7 6 5 4 3 2 1 0<br />

bitclockdelay bitclockdelay bitclockdelay bitclockdelay mode 0 0 0<br />

Bit 3 Bit 2 Bit 1 Bit 0<br />

bitclockdelay: 0 ... 15 dec possible<br />

mode: 0 ... start a FFT<br />

1 ... no FFT<br />

READ/WRITE DEVICE - HOST<br />

0x02 Status BCC<br />

Status:<br />

0 ... no error<br />

-1 ... SERIAL ERROR<br />

-8 ... ACKNOWLEDGEMENT ERROR<br />

The DSP did not send a correct acknowledge.<br />

The error leads to a reset of the read/write device.<br />

Page 59 (107)<br />

Protokoll HTRM801 V1.2/C