Communication Reader-Host Rev. 1.2 February 1999<br />

3.8.8 KI_Write_Secret2<br />

This command writes new HITAG 2 personalization data (4 data bytes) into the EEPROM of the<br />

read/write device.<br />

This command requires the old data to be transmitted as well, which means that data can only be<br />

changed if the user knows the old written data.<br />

Access rights and conformity between the sent old data and the stored data are verified before<br />

command execution.<br />

C-Function: void KI_Write_Secret2 (BYTE_T num, DWORD_T od, DWORD_T nd);<br />

Header-File: HitagKeyInit. H<br />

Serial protocol:<br />

HOST - READ/WRITE DEVICE<br />

7 0 ----- 31 24 7 0 ----- 31 24<br />

0x0B 'W' num OD[0] ----- OD[3] ND[0] ----- ND[3] BCC<br />

num: defines which information is to be written<br />

0x00 ... KEY LOW<br />

0x01 ... KEY HIGH<br />

0x02 ... Password TAG<br />

0x03 ... Password RWD<br />

OD[0] ... OD[3]: Old data<br />

ND[0] ... ND[3]: New data to be written<br />

READ/WRITE DEVICE - HOST<br />

0x02 Status BCC<br />

Status: 0 ... no error<br />

- 1 ... SERIAL ERROR (in this case the error can also mean, that the read/write<br />

device is not in the KeyInit Mode!)<br />

- 11 ... EEPROM WRONG OLD DATA<br />

- 12 ... EEPROM WRITE PROTECTED.<br />

If any error occurs, KeyInit Mode is exited immediately.<br />

Protokoll HTRM801 V1.2/C Page 72 (107)