Communication Reader-Host Rev. 1.2 February 1999<br />

3.7.44 RWD_Set_BCD_Offset<br />

This Long Range Reader command writes a new BCD (BitClockDelay) -Offset value into the<br />

EEPROM of the read/write device. This value adjusts the difference of the timing between<br />

HITAG 1 and HITAG 2 transponders.<br />

ATTENTION: It is not necessary to use this command when working with Philips Long Range<br />

Readers because EEPROM is already initialized to following standard value:<br />

bcd_offset = 5<br />

C-Function: void RWD_Set_BCD_Offset (BYTE_T bcd_offset);<br />

Header-File: HitagRWD.H<br />

Serial protocol:<br />

HOST - READ/WRITE DEVICE<br />

0x03 0xA4 bcd_offset BCC<br />

READ/WRITE DEVICE - HOST<br />

0x02 Status BCC<br />

Status:<br />

0 ... no error<br />

-1 ... SERIAL ERROR<br />

3.7.45 RWD_Read_LR_Status<br />

This Long Range Reader command reads the antenna overload bit. In case of broken or badly<br />

detuned antenna the overload bit is high.<br />

C-Function: void RWD_Read_LR_Status (void);<br />

Header-File: HitagRWD.H<br />

Serial protocol:<br />

HOST - READ/WRITE DEVICE<br />

0x02 'r' 0x70<br />

READ/WRITE DEVICE - HOST<br />

0x02 Status BCC<br />

Status:<br />

0 ... no error<br />

-1 ... SERIAL ERROR<br />

-20 ... ANTENNA OVERLOAD<br />

Protokoll HTRM801 V1.2/C Page 60 (107)