5 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS T2130<br />
U11 and U12 EEPROMS are from S. P. Radio initialized and programmed with certain constants related<br />
to the specific T2130, where the TX-processor is located. The constants are saved in the EEPROMS by<br />
means of service programmes.<br />
When any of the EEPROMS are replaced both must be initialized again and the T2130 must be calibrated.<br />
Refer to the service programmes.<br />
When the TX-processor board is replaced or is moved to another T2130, the T2130 must be calibrated<br />
again. Refer to the service programme.<br />
FILTER MODULE DRIVER<br />
The filter module driver activates all relays on the Output Filter (2). It consists of a serial to parallel shift<br />
register U10, 74HC595 and 8 open collector Darlington drivers located in U08 and U09 (MC1413/<br />
ULN2003).<br />
The filter module driver is connected to the serial device bus and is supplied from the +5VA. The +15V<br />
is connected to U08 and U09 <strong>for</strong> protection purposes.<br />
A/D CONVERTER AND SURROUNDING CIRCUITS<br />
The A/D converter (ADC) converts the following analog signals to digital values:<br />
- <strong>for</strong>ward voltage, (V<strong>for</strong>w)<br />
- reverse voltage, (Vrev)<br />
- +24V sense<br />
- temperature in PA (converted to a voltage)<br />
The ADC (U17, ADCO834) is an 8 bit converter and a 4 channel multiplexer (MUX). Data in and out are<br />
serial.<br />
The ADC is connected to the serial device bus and to a reference voltage, +5.00V to the Vref input (pin<br />
9). It is possible to switch the V<strong>for</strong>w to the Vref input (pin 9) on the ADC and to make a rathiometric<br />
measuring with V<strong>for</strong>w and Vref as inputs giving the parameter RHO direct.<br />
Figure 4: Measuring V<strong>for</strong>ward, +24V Sense and Temperature.<br />