3 SERVICE T2130<br />
3.4.2 OUTPUT FILTER (MODULE 2)<br />
3.4.2.1 ERROR 71. VFORWARD LOW<br />
3.4.2.2<br />
Check if the error comes up on all frequencies (one in each filter). Fault is probably in relay RE14-2 or<br />
in the cabling from module 2 to the Connection Board (6).<br />
If the error only comes up in one filter, check the input/output relays (eg. RE01-2, RE07-2), and then the<br />
filter capacitors.<br />
3.4.2.3<br />
Check of the V<strong>for</strong>ward detector.<br />
Select service programme SP-29, see chapter 3.9.<br />
3.4.2.4<br />
Measure the RF-output voltage on the Connection Board (6) with an oscilloscope approx. 200 Vp-p.<br />
Then check the DC voltage on U01/1 pin 1 approx. 6.5V.<br />
3.4.2.5 ERROR 78. INTERNAL SWR TOO HIGH<br />
3.4.2.6<br />
Check R27 and R28 (the power resistors to the left of module 6) with an ohmmeter value 50 ohm ±10%.<br />
3.4.2.7<br />
Check relay RE14.<br />
3.4.2.8 ERROR 73 AND 75<br />
Connect a 50 ohm load to the output terminal on the Connection Board (6).<br />
Select service mode SP-29, see chapter 3.9.<br />
3.4.2.9<br />
Check<br />
V<strong>for</strong>ward U1 pin 1 approx. 6.5 V<br />
Vreverse U1 pin 7 approx. 10.5 mV.<br />
3.4.2.10<br />
IF V<strong>for</strong>ward and Vreverse are ok. Then the fault is in TX-Processor (3)<br />
PAGE 3-6