3 SERVICE T2130<br />

If the error has appeared because of an error in the measuring circuit, please refer to section 3.5.3.1. A/<br />

D CONVERTER, +24 Volt Sense Measuring, in the instruction <strong>manual</strong> <strong>for</strong> T2130.<br />

77. TEMPERATURE SENSOR ERROR<br />

The temperature is measured to be very high or very low, indicating an error in the temperature measuring<br />

circuit. Please refer to section 3.5.3.1. A/D CONVERTER, Temperature Measuring in the instruction<br />

<strong>manual</strong> <strong>for</strong> T2130.<br />

78. INTERNAL SWR TOO HIGH<br />

The SWR in the internal dummy load used <strong>for</strong> the automatic power setting is higher than certain limits.<br />

For frequencies lower than 20 MHz the SWR is 1.2.<br />

For frequencies above 20 MHz the SWR limit is 1.6.<br />

Please refer to the circuit description <strong>for</strong> the Output Filter (2) section 3.4.2. in the instruction <strong>manual</strong> <strong>for</strong><br />

T2130.<br />