2 INSTALLATION MECHANICAL HF SSB TRANSMITTER T2130<br />

- When the handset key is released after a transmit period.<br />

- When the T2130 is ready to transmit after the ‘TX’ and ‘Tune’ keys have been activated.<br />

- When the ‘Enter/Stop’ key is pressed while the Automatic Power setting or the tuning of the AT2110<br />

takes place.<br />

OPEN AERIAL<br />

This command sets the relays in the AT2110 so that the aerial is disconnected from the HF SSB<br />

radiotelephone.<br />

SERVICE<br />

This command is always given associated with a service subcommand. There are several service<br />

subcommands, each corresponding to a given Service Programme. The answer consists of option (A) or<br />

(B) followed by 5 ASCII characters which are displayed in the lower part of the display in the RE2100.<br />

2.3.3.2 AUTOMATIC POWER SETTING<br />

MOTIVE FOR THE AUTOMATIC POWER SETTING<br />

The automatic setting of the power level is done to ensure the maximum RF-level out of the transmitter<br />

T2130, regardless of<br />

- variations in the RF-level out of the RE2100 exciter,<br />

- RF-loss due to long cables between RE2100 and T2130,<br />

- variations in the gain in the Power Amplifier from one to another,<br />

- variations in the gain in the Power Amplifier due to the frequency,<br />

- variations in the loss in the Output Filter module from one to another,<br />

- variations in the loss in the Output Filter module due to the frequency,<br />

- battery voltage supplying the Power Amplifier.<br />

(variations in the DC loss in the Power Supply).<br />

PRINCIPLES FOR THE AUTOMATIC POWER SETTING<br />

The RF-level out of the RE2100 exciter is increased in steps until a predetermined maximum allowable<br />

V<strong>for</strong>ward level out of the Output Filter (2) is reached.<br />

EVENTS FOR STARTING THE AUTOMATIC POWER SETTING<br />

The automatic power setting is done because of one of the following events:<br />

- The TX-frequency is changed and the key on the handset has been activated.<br />

- The TX-Tune key on the keyboard is pushed.<br />

- The time elapsed since latest automatic power setting is more than approx. 4 minutes.<br />

NECESSARY SIGNALS AND PARAMETERS<br />

- V<strong>for</strong>ward.<br />

The RF-level is measured by SWR-detector circuitry on the Output Filter (2) and is mentioned as<br />

‘V<strong>for</strong>ward’. V<strong>for</strong>ward is measured by the TX-processor (3) by means of an analog to digital converter.<br />