technical manual for sailor compact hf ssb t2130 - Gopher Proxy
technical manual for sailor compact hf ssb t2130 - Gopher Proxy
technical manual for sailor compact hf ssb t2130 - Gopher Proxy
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
2 INSTALLATION MECHANICAL HF SSB TRANSMITTER T2130<br />
2.3.3 SYSTEM FUNCTIONAL DESCRIPTION<br />
This section describes mainly the overall functions of the software in the T2130.<br />
The main functions are described in sections, where section 2.3.3.1. SP-BUS COMMUNICATION TO<br />
2130 is a common section to be read in conjunction with the others.<br />
In order to have the full understanding of the mode of operation of the T2130, section 2.3.3. SYSTEM<br />
FUNCTIONAL DESCRIPTION has to be read together with section 5. CIRCUIT DESCRIPTION.<br />
This section describes the following functions:<br />
- 2.3.3.1 SP-BUS COMMUNICATION TO T2130<br />
- 2.3.3.2 AUTOMATIC POWER SETTING<br />
- 2.3.3.3 TUNING THE AT2110<br />
- 2.3.3.4 TRANSMIT SUPERVISING<br />
- 2.3.3.5 CALIBRATION OF THE T2130<br />
2.3.3.1 SP BUS COMMUNICATION TO T2130<br />
The SP-Bus is a time-multiplexed serial data bus. The RE2100 is the master and the T2130 is one of<br />
several slaves. The T2130 is assigned a given slave address. RE2100 initiates and controls all<br />
communication to the T2130. This means that all activities per<strong>for</strong>med in T2130 is controlled by the<br />
RE2100.<br />
The T2130 may receive a number of commands according to the expected action in the T2130. When the<br />
T2130 has received a message it must replay immediately. The T2130 has four different options to answer<br />
the RE2100:<br />
A: The received command is understood and is executed.<br />
B: The received command is understood and T2130 is busy executing the command.<br />
C: The received command is understood and is executed. The T2130 has in<strong>for</strong>mation <strong>for</strong> the<br />
RE2100.<br />
D: A communication error is detected. The command is not executed. The error can be a parity<br />
error or a message length error.<br />
The answer options A, B, and C may be followed by in<strong>for</strong>mation related to the specific command. If the<br />
T2130 does not answer the RE2100, the RE2100 is repeating the command a number of times.<br />
If the T2130 does still not answer, an error (Error 20) will occur in the display in the RE2100.<br />
COMMANDS AND ANSWERS.<br />
In the following the commands to the T2130 and the answers from T2130 are described.<br />
SYNCRONIZE/STATUS AND ERROR CODE<br />
This command/answer is used in two situations:<br />
PAGE 2-24<br />
9315