3 SERVICE T2130<br />
NOTE:<br />
This is just checking the measuring circuit - NOT the absolute battery voltage present at the<br />
Connection Board (6).<br />
The special sequence of SP-29 followed by SP-20-0 may give a different battery voltage<br />
compared to a normal read of SP-20-0 caused by an offset added by the calibration of the<br />
T2130.<br />
TEMPERATURE MEASURING<br />
Test set-up: Mode 1.<br />
A: Disconnect the PO1 on the Power Supply (4). This is the cable to the temperature sensor R45 on the<br />
Power Amplifier (1).<br />
Connect a resistor of 2 Kohm on the PO1 on the Power Supply (4).<br />
B: Connect a Voltmeter to the lower end of R60, (8K2). Voltage is 2.5 Volt +/-1.7% +/- tolerances on the<br />
2 Kohm resistor.<br />
C: Calculate an adctemp:<br />
Measured voltage * 255<br />
adctemp = ----------------------------------<br />
5.0 Volt<br />
D: Enter SP-21-1 >ENT