21.06.2014 Views

technical manual for sailor compact hf ssb t2130 - Gopher Proxy

technical manual for sailor compact hf ssb t2130 - Gopher Proxy

technical manual for sailor compact hf ssb t2130 - Gopher Proxy

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3 SERVICE T2130<br />

NOTE:<br />

This is just checking the measuring circuit - NOT the absolute battery voltage present at the<br />

Connection Board (6).<br />

The special sequence of SP-29 followed by SP-20-0 may give a different battery voltage<br />

compared to a normal read of SP-20-0 caused by an offset added by the calibration of the<br />

T2130.<br />

TEMPERATURE MEASURING<br />

Test set-up: Mode 1.<br />

A: Disconnect the PO1 on the Power Supply (4). This is the cable to the temperature sensor R45 on the<br />

Power Amplifier (1).<br />

Connect a resistor of 2 Kohm on the PO1 on the Power Supply (4).<br />

B: Connect a Voltmeter to the lower end of R60, (8K2). Voltage is 2.5 Volt +/-1.7% +/- tolerances on the<br />

2 Kohm resistor.<br />

C: Calculate an adctemp:<br />

Measured voltage * 255<br />

adctemp = ----------------------------------<br />

5.0 Volt<br />

D: Enter SP-21-1 >ENT