3 SERVICE T2130<br />
3.4.4.9<br />
If the wave<strong>for</strong>ms look like that, the drain/source current is too high, Check <strong>for</strong> a defect rectifier diode or<br />
a defect regulator (U02 to U06).<br />
3.4.4.10<br />
If the wave<strong>for</strong>ms look like under point 3.4.4.6, then Q2 or Q3 is defect, It might also be a fault in the feedback<br />
circuit (D23, OC01)<br />
PAGE 3-9