Command Reference - Stollmann
Command Reference - Stollmann
Command Reference - Stollmann
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
TA+USBA <strong>Command</strong> <strong>Reference</strong> 1.01/06.2007<br />
2. Using the TA+USB<br />
2.2.2 AT command S register set<br />
The available S-Parameters are listed below and can be stored to the user profile by<br />
entering the “AT&W” command.<br />
The modem selects an S-Parameter, performs an S-Parameter read or write<br />
function, or reports the value of an S-Parameter.<br />
ATSn=v Set S-Parameter n to the value v.<br />
ATSn? Reports the value of S-Parameter n<br />
If the number “n” is outside of the range of the available S-Parameter or the value<br />
“v” is outside the range permitted for the given S-Parameter, the mode will return the<br />
ERROR message.<br />
Some S-Parameters are read only.<br />
S0<br />
Number of Rings to Auto-Answer<br />
S0 set the number of the rings required before the TA automatically answers a call.<br />
Setting this parameter to “0” disables auto-answer mode.<br />
S0 0: No automatic call acceptance, acceptance of an incoming call is<br />
controlled by the data terminal (command ATA after RING)<br />
1: Immediate call acceptance by the terminal adapter<br />
2..n: Call acceptance through the terminal adapter after n "RING"<br />
messages.<br />
The serial status line "RI" will toggle during the active "RING" state uniformly<br />
distributed according the half time of register S80.<br />
Note: The time interval to display the incoming call (“RING” or “2”) can be<br />
configured with the S-register S80.<br />
S1<br />
Ring Counter<br />
S1 is incremented each time the TA signals the RING message to the serial<br />
interface. This parameter is read only.<br />
Note: If parameter S0 is set to “0” the ring counter is disabled.<br />
30 © <strong>Stollmann</strong> Entwicklungs- und Vertriebs-GmbH