TA+USBA <strong>Command</strong> <strong>Reference</strong> 1.01/06.2007<br />
2. Using the TA+USB<br />
S12<br />
Escape Sequence delay time<br />
S12 controls the delay time (in 10ms steps) before and after the Escape Character<br />
configured in the parameter ATS2 to switch from the online data mode to the online<br />
command mode.<br />
The default value is set to “100” which equals 1 second.<br />
Example for the default escape sequence:<br />
<br />
S16<br />
Last occurred CAPI/ISDN cause<br />
S16 reports the last occurred internal CAPI cause or ISDN error cause.<br />
This parameter is read only is will not be saved in the stored configuration profile.<br />
ATS16?<br />
Reports the last occurred CAPI/ISDN error cause<br />
S20<br />
<strong>Command</strong> Line timeout<br />
S20 controls the timeout for the current command line if no Carriage Return<br />
character (ATS3, end of line character) was sent.<br />
The timer is started after each received command line character from the serial<br />
interface. When no Carriage Return character (i.e. 0x0D) was received after the<br />
timer expired, the complete command line parameter list is erased.<br />
The default value is set to “30” seconds.<br />
This timer is available in the command mode only.<br />
S30 Suppress sending the Escape Sequence [+++]<br />
S30 controls the behaviour of transmitting the Escape Sequence Character (ATS2)<br />
as a data stream to the destination side.<br />
ATS30=0<br />
ATS30=1<br />
Escape characters will not be sent<br />
Escape characters will be sent (default)<br />
32 © <strong>Stollmann</strong> Entwicklungs- und Vertriebs-GmbH