Command Reference - Stollmann
Command Reference - Stollmann
Command Reference - Stollmann
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
TA+USBA <strong>Command</strong> <strong>Reference</strong> 1.01/06.2007<br />
3. TA+Configurator command set<br />
3.4 List of TA+Configurator commands<br />
The TA+Configurator commands typed in must have the correct syntax and be<br />
complete, including all blanks. Capital/small letter use is not important. The entry is<br />
not case sensitive.<br />
The bolded values are factory defaults. The usage is:<br />
[?][=parameter]<br />
Example to set the ISDN B channel protocol to X.75:<br />
prot=10<br />
Example to show the selected ISDN protocol:<br />
prot<br />
Example to show all selectable ISDN protocols:<br />
?prot<br />
To get an overview about the commands of your TA some major commands here as<br />
a preview:<br />
show show the usually used parameter<br />
showall show all changeable parameter<br />
quit leave TA+Configurator<br />
help show all available commands<br />
defa setup default parameter set<br />
defa 1 setup factory default parameter set<br />
save store parameter non volatile<br />
at.sx, at.opt, at.rcs<br />
S-Register, AT command parameter set<br />
Handle AT command set specific settings.<br />
Show and change AT S registers by entering the new value.<br />
AT.Sn=v set Register Sn to value v<br />
AT.Sn? show current value of S-Register Sn<br />
The complete list of S-Register is described in chapter 3.2.2.<br />
“AT command S register set”.<br />
at.opt<br />
at.rcs<br />
show option register (bit-values):<br />
bit 0 : 01 => ATE1<br />
bit 1 : 02 => ATQ1<br />
bit 2 : 04 => ATV1<br />
bit 5 : 32 => ATW1<br />
equals setting of Hayes "ATX" command<br />
46 © <strong>Stollmann</strong> Entwicklungs- und Vertriebs-GmbH