(b)<br />

(ii)<br />

<strong>Australian</strong> <strong>Building</strong> <strong>Codes</strong> <strong>Board</strong> Page 7<br />

Deemed-to-Satisfy Provisions<br />

the length is measured 500 mm from the inside edge of the landing; and<br />

have— a non-slip finish throughout or an adequate non-skid strip near the<br />

edge of the landing where it leads to a flight below; and<br />

(A)<br />

(B)<br />

in a Class 9a building—<br />

(i)<br />

(ii)<br />

a surface with a slip-resistance classification complying with Table<br />

D2.14 when tested in accordance with AS 4586; or<br />

a strip at the edge of the landing with a slip-resistance classification<br />

complying with Table D2.14 when tested in accordance with AS 4586,<br />

where the edge leads to a flight below; and<br />

the area of any landing must be sufficient to move a stretcher, 2 m long and<br />

600 mm wide, at a gradient not more than the gradient of the stairs, with at<br />

least one end of the stretcher on the landing while changing direction<br />

between flights; or<br />

the stair must have a change of direction of 180°, and the landing a clear<br />

width of not less than 1.6 m and a clear length of not less than 2.7 m.<br />

Table D2.14 SLIP-RESISTANCE CLASSIFICATION<br />

Application<br />

Dry<br />

Surface conditions<br />

Wet<br />

Ramp steeper than 1:14 P4 or R11 P5 or R12<br />

Ramp not steeper than 1:14 P3 or R10 P4 or R11<br />

Tread or landing surface P3 or R10 P4 or R11<br />

Nosing or landing edge strip P3 P4<br />

D2.15 Thresholds<br />

The threshold of a doorway must not incorporate a step or ramp at any point closer to the<br />

doorway than the width of the door leaf unless—<br />

(a)<br />

(b)<br />

in patient care areas in a Class 9a health-care building, the door sill is not more<br />

than 25 mm above the finished floor level to which the doorway opens; or<br />

in a Class 9c aged care building, a ramp is provided with a maximum gradient of<br />

1:8 for a maximum height of 25 mm over the threshold; or<br />

NSW D2.15(d),(e)<br />

(c)<br />

(d)<br />

in a building required to be accessible by Part D3, the doorway—<br />

(i)<br />

(ii)<br />

opens to a road or open space; and<br />

is provided with a threshold ramp or step ramp in accordance with<br />

AS 1428.1; or<br />

in other cases—<br />

(i)<br />

PUBLIC COMMENT DRAFT<br />

the doorway opens to a road or open space, external stair landing or external<br />

balcony; and<br />

NCC2014 Volume One D2.15